- 8 -
2.3 How to Order
The part number construction for this product is as follows:
L E C P 6 N □ □ - □
Electric actuator model
Controller
Compatible
Number of step data
Parallel I/O type
I/O cable length Note 1) Specified software (LEC-BCW) is required.
Option
Caution
The controller and the electric actuator are factory set Confirm the combination of the
controller and the electric actuator is correct.
<Check the following before use.>
(1) Check the electric actuator label for the model number. Check that this matches the controller.
(2) Check Parallel I/O configuration matches (NPN or PNP)
Controller
(1) (1)
(2)
P
Step motor (Servo / 24 VDC)
6
64 data
N
NPN type
P
PNP type
Nil
None
1
1.5m
3
3m
5
5m
Nil
Screw mounting
D
DIN rail mounting
LEFS25B-100
N P N
LEFS25B-100
Electric actuato
r
Blank controller
*1)
BC
Stroke example: For LEFS25B-100B-S36N1,
specify LEFS25B-100.
Rotating angle: For LER10K-2L-R16N1D,
specify LER10K-2.
(Enter from the electric actuator part number
“LE”
to
“stroke/ rotating angle”)