- 25 -
Controller
power supply
5.4 Stop circuits
When the external switch to stop or the stop switch of the teaching box is enabled on this controller, the
electric actuator will stop.
(1) Example circuit 1 - Single controller with teaching Box
When the teaching box is connected to the controller, the teaching box
’s stop switch will become
effective.
Warning
The teaching box’s stop switch is effective only to the controller that is connected with it.
Stop switch
Stop signal
EMG
C24V
M24V
0V
Power
supply plug
Controller
Teaching box is not
connected.
Teaching box is
connected.
CN1
Teaching box
(with 3m cable)
CN4
External stop circuit
24V
0V