IDX-OM-W089
Air Dryer
15 Specification for Option V
IDFA6E-20 15 - 1 15-2 Specifications
15-2
Specifications
The timer is set to have ON time of 0.5sec and OFF time
30sec of min. at the time of
shipment from the factory. Do not change this timer setting. If it is changed, water could
be discharged from the outlet line of the dryer. Service parts number will change
depending on the power supply voltage of the dryer.
※
Please refer to page 6-3 or 14-3 for the electrical diagram.
15-3
How to perform maintenance
The product needs to be maintained. Clean it in the following procedure periodically.
1) Close the ball valve.
2) Press the test switch and make the residual pressure is released.
3) Remove the strainer and clean it.
4) Reassemble the strainer and open the ball valve.
Order number (service parts)
IDF-S0198
Max. operating pressure
1.6MPa
ON time ( Valve: open)
0.5sec
OFF time ( Valve: close) 30sec
ON
OFF
ON:SEC
OFF:MIN
0.5
2
4
6
8
10
0.5
1
2
3
4
5
Built-in strainer
Ball valve
Test switch
Strainer lid