Air Dryer
6 References
IDFA6E-20
6 - 4
36-4Compressed Air and Refrigerant
Circuit/Operation Principles
IDX-OM-W089
6 - 4
Compressed Air and Refrigerant Circuit/Operation Principles
THERMOMETER
EVAPORATION
DRAIN
VALVE
REGULATING
CAPACITY
COMPRESSOR
FAN MOTOR
CONDENSER
PRESSURE SWITCH
CAPILLAY TUBE
HEAT EXCHANGER
AUTO DRAIN
AIR INLET
AIR OUTLET
COMPRESSED
COMPRESSED
Compressed Air Circuit
Humid hot air entering air dryer is cooled in the cooler. At this time, the condensate is separated from the air by
the drain separator and automatically discharged. The dry air is heated by the re-heater until it gets about the
same temperature as that of ambient air. It is then discharged from air dryer outlet.
Refrigerant Circuit
The freon gas charged in the refrigerant circuit is compressed by the compressor and cooled by the condenser to
become liquid. Then, going through the capillary tube, the refrigerant pressure and temperature (evaporating
temperature) decreased rapidly.
Passing through the cooler part, it draws heat from the hot compressed air and
intensely boils. Finally, it is sucked into the compressor again. The hot gas bypass valve opens to prevent
drain
from freezing when compressed air is too cold.