Air Dryer
6 References
IDFA6E-20
6 - 1
6-1 Specifications
IDX-OM-W089
6
6
6
6
References
6 - 1
Specifications
Model
Specification
IDFA6E-20-
□
R
a
te
d
C
o
n
d
it
io
n
Air Flow Rate
m
3
/min
(ANR)(Note 1)
50Hz
0.75
60Hz
0.82
Operating Pressure
0.7MPa
Inlet Air Temperature
35
℃
Ambient Temperature
32
℃
Outlet Pressure
Dew
Point
10
℃
O
p
e
ra
ti
n
g
R
a
n
g
e
Working Fluid
Compressed Air
Inlet Air Temperature
5
~
50
℃
MIN.Inlet Air Pressure
0.15MPa
MAX.Inlet Air Pressure
1.0Mpa
Ambient Temperature
2 ~ 40
o
C(Relative Humidity of 85% or less)
E
le
c
tr
ic
a
l
S
p
e
c
if
ic
a
ti
o
n
Power source
1Phase
AC200/200,220V
±
10%
(
50/60Hz
)
Starting
current
A
AC200V
(
50/60Hz
)
9/8
Operating
current
A
AC200V
(
50/60Hz
)
1.2/1.3
Power
Sonsumption
W
AC200V
(
50/60Hz
)
180/202
Circuit Breaker
Rated current
:
5A
Sensitive current
:
30mA
Condenser
Air cooling
Refrigerant
R134a(HFC)
[GWP
:
1430]
Refrigerant Charge Quantitiy
g
230±5
Air IN/OUT Connection
Rc3/4
Drain Connection
(Outside Diameter of Tubing)
10mm
Color
Panel: Urbanwhite1
Base:Urbangray2
Weight
kg
23
Application air compressor output
(Reference) kW
5.5
Note1: The data for m3/
h
(ANR) is referring to the conditions of 20
°
C, 1atm . pressure & relative humidity
of 65%.
Note 2: The value is that of operation under rated condition.
Note 3: Install GFCI breaker that comes with sensivity of 30mA.
Note 4: When short period power shortage (including instantly recovered shortage) is recovered, it may
take a longer starting period than usual starting or may not start due to the protective devices.
Summary of Contents for IDFA6E-20-A
Page 47: ......