Installation conditions
System installation is not allowed outside or in the conditions described below.
Potential system malfunction and damage may occur if disregarded.
Clean room specifications are not applied to this system. The pump and ventilating
fan installed in this system generate particles.
Location that is exposed to water, water vapor, salt water, and oil
Location that is exposed to dust
Location that is exposed to corrosive gas, organic solvent, chemical solution,
and flammable gas (this system is not flame-proof)
Location where ambient temperature is out of the following range:
In transportation
-40 to 70°C (with no water or circulating fluid in piping)
In storage
0 to 50°C (with no water or circulating fluid in piping)
In operation
10 to 35°C
Location where ambient humidity is out of the following range or where
condensation forms:
In transportation and storage
15 to 85%
In operation
30 to 70%
Location that is exposed to direct sun light or radiant heat
Location that is near heat sources and poor in ventilation
Location that is subjected to abrupt changes in temperature
Location that is subjected to intense electromagnetic noise (intense electric field,
intense magnetic field, or surges)
Location that is subjected to static electricity, or condition that discharges static
electricity to the system
Location that is subjected to strong high frequencies
Location that is subjected to potential lightning damage
Location with altitudes of 1000m or higher (except for system storage and
transport)
Location that is affected by strong vibrations or impacts
Condition that applies external force or weight causing the system deformation
Condition with no adequate space for maintenance as required
Summary of Contents for HRW002-H
Page 6: ...HRX OM K003 Table of Contents HRW Series TOC 4...
Page 22: ...HRX OM K003 Chapter 1 Safety 1 8 Material Safety Data Sheet MSDS HRW Series 1 16...
Page 24: ...HRX OM K003 Chapter 2 Name of Each Section 2 1 Name of Each Section HRW Series 2 2...
Page 60: ...HRX OM K003 Chapter 5 System Operation 5 4 Examples of System Operation HRW Series 5 16...
Page 64: ...HRX OM K003 Chapter 6 Error Message and Troubleshooting 6 2 Troubleshooting HRW Series 6 4...
Page 86: ......