HRX-OM-S010
Chapter 2 Contact input/output communication
2.4
Setting and checking
HRS100/150 Series
2-4
2.4 Setting and checking
2.4.1
Setting and checking
The table below explains the setting items of the contact input/output signal
and the initial values.
Table 2.4-1
List of set communication items
Display
Item
Contents
Default setting
Communication mode
Sets communication mode of this product.
LOC
Contact input signal 1
Sets the function of contact input signal 1.
RUN
Contact input signal 1 type
Sets input type of contact input signal 1. [----] is
displayed when the setting of contact input signal 1 is
OFF.
ALT (----)
Contact input signal 1 delay
timer of reading
Sets the delay timer of reading of contact input signal
1. Used when the setting of the contact input signal 1
is SW_A or SW_B. [----] is displayed when the setting
of the contact input signal 1 is not SW_A or SW_B.
---- (0)
Contact input signal 1 OFF
Detection timer
Sets the OFF detection timer of contact input signal
1. Used when the setting of the contact input signal 1
is SW_A or SW_B. [----] is displayed when the setting
of the contact input signal 1 is not SW_A or SW_B.
---- (0)
Contact input signal 2
Sets the function of contact input signal 2.
OFF
Contact input signal 2 type
Sets input type of contact input signal 2. [----] is
displayed when the setting of contact input signal 2 is
OFF.
ALT (----)
Contact input signal 2 delay
timer of reading
Sets the delay timer of reading of contact input signal
2. Used when the setting of the contact input signal 2
is SW_A or SW_B [----] is displayed when the setting
of the contact input signal 2 is not SW_A or SW_B.
---- (0)
Contact input signal 2 OFF
Detection timer
Sets the OFF detection timer of contact input signal
2. Used when the setting of the contact input signal 2
is SW_A or SW_B. [----] is displayed when the setting
of the contact input signal 2 is not SW_A or SW_B.
---- (0)
Contact output signal 1
function
Sets output signal function of contact output 1.
RUN
Contact output signal 1
operation
Sets output signal operation of contact output 1.
A
Contact output signal 1
selected alarm
Sets alarm which is selected for contact output 1.
[----] is displayed when the setting of the output signal
of contact output1 is not selected alarm signal.
---- (AL.01)
Contact output signal 2
function
Sets output signal function of contact output 2.
RMT
Contact output signal 2
operation
Sets output signal operation of contact output 2.
A
Contact output signal 2
selected alarm
Sets alarm which is selected for contact output 2.
[----] is displayed when the setting of the output signal
of contact output2 is not selected alarm signal.
---- (AL.01)
Contact output signal 3
function
Sets output signal function of contact output 3.
ALM
Contact output signal 3
operation
Sets output signal operation of contact output 3.
B
Contact output signal 3
selected alarm
Sets alarm which is selected for contact output 3.
[----] is displayed when the setting of the output signal
of contact output3 is not selected alarm signal.
---- (AL.01)