-6- 

 

No.EX##-OMM0008-B  

 

 

*Environment 

Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or 

steam. 

Otherwise failure or malfunction can result. 

Do not use in an area where surges are generated. 

If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction 
furnace, motor, etc.) close to the SI unit, this may cause deterioration or breakage of the internal circuit of the SI 
unit. Avoid sources of surge generation and crossed lines. 

Prevent foreign matter such as remnant of wires from entering the SI unit to avoid failure and 

malfunction. 

Mount the product in a place that is not exposed to vibration or impact. 

Otherwise failure or malfunction can result. 

Do not use the product in an environment that is exposed to temperature cycle. 

Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product. 

Do not expose the product to direct sunlight. 

If using in a location directly exposed to sunlight, shade the product from the sunlight. 
Otherwise failure or malfunction can result. 

Keep within the specified ambient temperature range. 

Otherwise malfunction can result. 

Do not operate close to a heat source, or in a location exposed to radiant heat. 

Otherwise malfunction can result. 

 

*Adjustment and Operation 

Set the switches by using a sharp-pointed screwdriver etc. 

It may damage set switches. 

Perform settings suitable for the operating conditions. 

Incorrect setting can cause operation failure. 
For details of each setting, refer to page 14 of this manual. 

Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. 

For the PLC protocol and programming refer to the relevant manufacturer's documentation. 

 

*Maintenance 

Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of 

air before performing maintenance. 

There is a risk of unexpected malfunction. 

Perform regular maintenance and inspections. 

There is a risk of unexpected malfunction. 

After maintenance is complete, perform appropriate functional inspections. 

Stop operation if the equipment does not function properly. 
Otherwise safety is not assured due to an unexpected malfunction or incorrect operation. 

Do not use solvents such as benzene, thinner etc. to clean the SI unit. 

They could damage the surface of the body and erase the markings on the body. 
Use a soft cloth to remove stains. 
For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains 
again with a dry cloth.

 

Summary of Contents for EX12-SCM Series

Page 1: ...No EX OMM0008 B PRODUCT NAME Fieldbus system SI unit compatible CompoNetTM MODEL Series Product Number EX12 SCM...

Page 2: ...ons 2 Product Summary 7 Model Identification and How to Order 7 Names and Functions of Product 8 Mounting and Installation 10 Wiring 10 Setting 14 Mounting of Objects 15 Maintenance 22 Troubleshooting...

Page 3: ...of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectl...

Page 4: ...lacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to u...

Page 5: ...n an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof If using the product in an interlocking circuit Provide a dou...

Page 6: ...may be broken Never mount a product in a location that will be used as a foothold The product may be damaged if excessive force is applied by stepping or climbing onto it Wiring Avoid repeatedly bend...

Page 7: ...not operate close to a heat source or in a location exposed to radiant heat Otherwise malfunction can result Adjustment and Operation Set the switches by using a sharp pointed screwdriver etc It may...

Page 8: ...for CompoNet TM CM3 PNP output for CompoNet TM Valve interface EX120 Plug in EX121 Flat ribbon cable DIN rail mounting EX122 Plug in DIN rail mounting Part number for accessories EX9 CCM1 Communicati...

Page 9: ...ply connector Connect to the power supply for solenoid valve 2 Communication connector Connect to the CompoNet TM network 3 Display The status of the unit is indicated by LED 4 Setting switch area For...

Page 10: ...a flat ribbon cable dedicated for use with CompoNetTM products Communication connector Terminal block connector for round cable VCTF EX9 CCM2 Not supplied with product Applied when a VCTF cable is use...

Page 11: ...10 No EX OMM0008 B Mounting and Installation Wiring Internal circuit NPN EX12 SCM1 PNP EX12 SCM3...

Page 12: ...tor Please contact OMRON for further details Connection of IDC connector for flat ribbon cable 1 Cutting of cable Cut the cable vertically Use a tool with sharp edges such as a nipper to prevent short...

Page 13: ...nector clicks into place Note Do not pressure weld the connector cover at the edges Do not pressure weld the connector cover at the back of the pressure welding block Set the connector in the correct...

Page 14: ...e crimping terminal used 3 Mounting of crimping terminal Use the crimping terminal for wiring Do not connect electrical wires which are just twisted directly to the terminal block 4 Mounting to the co...

Page 15: ...ation error Red lights up Minor communication error Red flashes Power supply off All lights go off Switch setting The node setting is conducted using the rotary switch inside the unit cover Make sure...

Page 16: ...0x0E Get_Attribute_Single The identify class is reset by software Restart the unit after that Message router object 0x02 Attributes Unsupport Object class Services Unsupport Attributes Unsupport Objec...

Page 17: ...Instance type 01H 0x03 Transport class trigger 80H 0x04 Produced connection ID 0x05 Consumed connection ID 0x06 Initial comm characteristics 01H 0x07 Produced connection size 64H 0x08 Consumed connect...

Page 18: ...s Services 0x0E Get_Attribute_Single ID Meaning GET SET Value 0x01 MAC ID 0x02 Data Rate 0x05 Allocation choice Attributes 0x0A Explicit message timer Cord Meaning Parameter option 0x0E Get_Attribute_...

Page 19: ...flected 0x65 Maintenance Counter Mode Choice Setting of mode of maintenance counter 0 Energizing time mode hour 1 Contact counter mode time The set value is immediately reflected 0x66 Maintenance Coun...

Page 20: ...k power supply voltage 0x6E Threshold Network Power Voltage Threshold of network power supply voltage When the voltage falls below this set value the status flag will turn on The set value is immediat...

Page 21: ...g Any of output monitored operation time is outside of range ON Communication Error Log object 0x96 ID Meaning GET SET Value 0x01 Revision 0003H Attributes 0x02 Max Instance 0004H Cord Meaning Paramet...

Page 22: ...threshold of output point with the product 0 Within threshold 1 Over threshold 0x67 Threshold Response Time Response time of machine of output point with the product units ms The set value is immediat...

Page 23: ...ng of specified range and balance change in pair cable If any breaks and found or the conductive resistance is incorrect replace the cable Refer to the cable specifications for the conductive resistan...

Page 24: ...noid valve s malfunction Only the LED at a solenoid valve is lit up See Trouble No 2 MS_LED at SI unit goes Red light of MS_LED at SI unit is lit up Red light of MS_LED at SI unit is blinking See Trou...

Page 25: ...S_LED goes off Master unit power supply failure Check the master unit is operating properly Connect the master unit to a proper power supply 5 SI unit MS_LED green on NS_LED red on Duplication of node...

Page 26: ...ly cable correctly Check there is no incorrect wiring of valve power supply Correct the wiring 8 SI unit MS_LED green on NS_LED green on PWR V _LED goes off Valve power supply failure Check proper sup...

Page 27: ...C 2 M or more Between external terminals and body Operating environment No corrosive gas and no dust Environm ent proof Pollution degree Pollution degree 3 2 Standard CE marking Weight EX120 SCM 100 g...

Page 28: ...27 No EX OMM0008 B Dimensions unit mm EX120 SCM...

Page 29: ...28 No EX OMM0008 B EX121 SCM...

Page 30: ...29 No EX OMM0008 B EX122 SCM...

Page 31: ...ory A Add the contents B Revision Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer CompoNet TM is a trademark of ODVA 2009 2011 SMC Cor...

Reviews: