-19-
No.EX##-OMM0008-B
Unit Manager object (0x95)
ID
Meaning
GET
SET
Value
Attributes
0x01 Revision
О
-
0001H
Cord
Meaning
Parameter option
Object class
Services
0x0E GET_Attribute_Single -
ID
Meaning
GET
SET
Value
0x65 Generic Status
О
-
General purpose
status
∗
1
0x6B Network Power Voltage
О
-
Network power
supply voltage
100 mV units
(BIN data)
0x6C
Max Network Power
Voltage
О
-
Max. network power
supply voltage
0x6D
Min Network Power
Voltage
О
-
Min. network power
supply voltage
0x6E
Threshold Network
Power Voltage
О
О
Threshold of
network power
supply voltage.
When the voltage
falls below this set
value, the status flag
will turn on.
The set value is
immediately reflected.
Default: 008CH
(14.0 V)
0x71 Run Hours
О
-
The unit for
energizing time of
internal power circuit
with the product.
Hour
0 to 4294967295
(00000000 to
FFFFFFFF H)
Attributes
0x72 Run Hours Exceed
О
-
Energizing time
threshold over flag
0: Energizing time <
Threshold (default)
1: Energizing time >=
Threshold
Cord
Meaning
Parameter option
0x05 Reset Attribute6C,
6D
0x0E Get_Attribute_Single -
Object instance
Services
0x10 Set_Attribute_Single -