-14-
No.EX##-OMM0008-B
Setting
•
LED indication
Display
Meaning
PWR (V)
Solenoid valve power supply ON : Lights up
Solenoid valve power supply OFF : Goes off
MS
Unit in normal operation : Green lights up
Fatal error : Red lights up
Minor error : Red flashes
Power supply off : All lights go off
NS
On line/Connection completed : Green lights up
On line/Connection not completed: Green flashes
Fatal communication error : Red lights up
Minor communication error : Red flashes
Power supply off : All lights go off
•
Switch setting
•
The node setting is conducted using the rotary switch inside the unit cover.
•
Make sure the switch setting is carried out with the power supply turned off.
•
The switch should be set using a small flat screwdriver.
Setting
Setting range
×
10
0 to 6
×
1
0 to 9
*1: The station number should be any number from 00 to 63.
If a node is set to a number greater than 63, the "NS" LED will
light up.
After turning the power off, set to the correct number.
*2: The address number cannot be duplicated.