19
6.
ACCESSORY INSTALLATION AND OPERATION
6.1 Remote control HA700R
The remote control allows you to activate several
functions of your station (Disarming, Total Arming,
Partial Arming, Panic and Test Mode).
The remote control has a Panic switch, that when
actuated causes immediately a complete alarm situation
if the system is in Armed or Disarmed mode (except if
the system is in Test mode).
The remote control uses one CR2032 Lithium battery,
which, in normal conditions, has a lifespan of more than
2 years. If the battery is in good condition, the remote
control LED turns on constantly when a key is pressed.
However, if the battery is low, the LED will flash when a
key is pressed. In this case, replace the battery as soon
as possible.
INSTALLING OR CHANGING THE BATTERY
- Using a coin, unscrew and remove the rear cover.
- If you change the battery, replace the old one.
- Insert the battery so that the side with the + mark is visible (not the printed circuit side).
- Close the cover.
IMPORTANT:
If you loose a remote control, you have to delete all remote controls saved in the station memory
(following the indications on page 14), then learn again the remote controls that you have.
6.2 Passive infrared movement detector (PIR) SA68P
PIR detectors are designed to detect movement in a protected area by detecting changes in infra-red
radiation levels caused when a person moves within or across the devices field of vision. If movement is
detected an alarm signal will be emitted, (if the system is armed and the alarm zone active).
Note:
PIR detectors will also detect animals, so ensure that pets are not permitted access to areas fitted
with Passive Infra-Red Detectors when the system is armed.
The PIR Detector adopts a 3.6V 1200mAh Lithium battery which under normal conditions will have typical
life in excess of 4 years. When the battery level drops, with the PIR in normal mode and the battery cover
fitted, the LED behind the detection window will flash upon detecting movement. When this occurs the
batteries should be replaced as soon as possible.
Batt
ery
A LED
E Panic switch
B Total arming F Key ring
C Partial arming G Negative polarity
D Disarming