17
- Enter
1234
(or your personal code), followed by
.
4.3 Chime mode
You can set the station into chime mode. In this mode, it will emit a "ding-dong" when you pass in front of a
movement detector or when you open a door/window equipped with a magnetic detector.
CAUTION:
In this mode the self-protections and the detectors saved in panic area will always be active and will
trigger the station.
To set the station into chime mode:
- Enter
1234
(or your personal code), followed by
3
.
4.4 Test mode
The station can be set in test mode in order to test the system or to operate on an accessory (e.g.: change a battery)
without to trigger the system (station, siren and/or transmitter).
To set the station into test mode:
- Enter
1234
(or your personal code), followed by
03
, the STATUS LED will light up once and a beep will be
emitted to confirm that the station is in test mode.
Accessory test
When the station is in test mode, actuate every system detector by walking in a protected area or by opening a
protected door/window. Every time a detector is activated, the station emits a beep to indicate that a signal has been
received.
You can also test the self-protection of every detector by opening its casing. At each activation of a self-protection,
the station emits a beep.
To test the remote control, just push each of its keys. Each time these keys are pressed, the station emits a beep.
Phone transmitter test
You can test the station phone transmitter to check that, for example, there is no connecting error.
To test the transmitter, push the key
9
for 3 seconds. Then the station will call the first number saved in its memory.
If you want to test all numbers, you have to simulate a real triggering and let the station ring without to stop it. To do
this test, you can set the station in silent mode (see page 11).
To exit the station from test mode:
- Push the key
*
, the STATUS LED will light up once and a beep will be emitted to confirm that the station have
left test mode.
NOTE: The station will exit test mode automatically after 10 minutes.