ALC404 LIGHTING TOWER CONTROLLER USER MANUAL
ALC404 Lighting Tower Controller 2018-11-06 Version 1.1 Page 49 of 83
Category
Parameters
Range
Default
Description
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 3 Set
Function
Config.
(0~119)
22 Common
Shutdown
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 4 Set
Function
Config.
(0~119)
106 1#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 5 Set
Function
Config.
(0~119)
107 2#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 6 Set
Function
Config.
(0~119)
108 3#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Output 7 Set
Function
Config.
(0~119)
109 4#Light
Output
7.11 FUNCTION
DEFINITION OF OUTPUT
PORTS.
Output Type
(0~1)
0 Open
0 Open
1 Close
Module
Config.
Language Select
(0~1)
0
0 Simplified Chinese
1 English
Power On Mode
(0~4)
0
0 Stop Mode
1 Manual Mode
2 Auto Timer Mode
3 Sunrise/Sunset Mode
4 Remote Start Mode
Password Config
(0~65533)
00318
‖00318‖ password is used
to enter into advanced
parameter settings.
Start Interface
Enable
(0~1)
0
0 Disabled 1 Enabled
Start
Interface
Delay
(0~3600)s
3
After enabled, it is the boot
screen duration that user
defined for each start.
Deep Sleep
Enable
(0~1)
0
0 Disabled 1 Enabled
Deep Sleep
(1~100)min
6
After enabled, no keys been