SMART Wallbox A0009069206 Instruction Manual Download Page 13

smart Wallbox   Charging procedure  9 

PLEASE NOTE!  

In principle, the charging procedure is always terminated by the vehicle, not by the wallbox. 
An illuminated green LED   indicates, on the basis of communication with the vehicle, that 
the charging procedure has been either paused or completed: Distinguishing these two op-
erating states is only possible by checking the battery charge indicator inside the vehicle. 
Should the vehicle not be fully charged after a sufficiently long charging process, please 
contact your local smart partner.

After the charging procedure has been completed, please remove the cable from the vehicle socket and 
store it appropriately in readiness for the next charging procedure.

Summary of Contents for Wallbox A0009069206

Page 1: ...smart Wallbox Instruction Manual ...

Page 2: ... local smart technical support This manual in its entirety or in parts must not be reproduced stored electronically or otherwise transmitted electronically electrically mechanically optically chemically by photocopy or as an audio recording without express written permission Version 1 1 SMART UM Wallbox 2017 03 06 Article No 0301490 ...

Page 3: ...el variant 03 7 Charging procedure 7 Charging procedure with the smart Wallbox 04 10 Resolving errors 10 Error messages during the charging procedure 11 Operational disruptions and solutions 11 Taking the product out of and back into operation 12 Frequently asked questions 05 14 Appendix 14 Technical specifications 15 Scale drawings and dimensions 16 Standards guidelines 17 CE certification and co...

Page 4: ......

Page 5: ...ases be passed on to each individual user or made available to them All measurements in this manual are in millimeters Where necessary the scale is indicated for differ ent illustrations Please note that all technical details specifications and design characteristics of the product may be changed without prior notice Safety notices in this manual In particular the warnings and safety measures in t...

Page 6: ... supply cable for the wallbox All smart Wallbox model variants described in this document have integrated DC fault current protection for which an RCCB with Type A tripping characteristic is generally sufficient However country specific and local reg ulations must always be observed These may prescribe an RCCB with a different tripping charac teristic e g Type B Please ensure that minimum clearanc...

Page 7: ...rent state of technology and fulfils all current technical safety requirements guidelines and standards The safety information provided in this manual serves to en sure the proper and safe operation of the device Disregard of or actions contrary to the safety infor mation and instructions contained in this manual may lead to electric shock fire and or severe injury Malfunctions affecting the safet...

Page 8: ...connect the wallbox completely from the power grid the power supply must be interrupted using the upstream fuse s and the external residual current circuit breaker RCCB Never operate the wallbox in a confined space In particular you must ensure that the vehicle can be parked at a suitable distance from the wallbox and connected without any strain on the charging cable A parking spot for the vehicl...

Page 9: ...ck the current operating status at any time Should a malfunction occur you can identify the cause by its specific LED error code without having to open the housing After be ing taken into operation by a specialist contractor the wallbox is ready for charging at any time while each charging process must be separately authorized via the integrated key switch A common characteristic of all wallboxes ...

Page 10: ... described in this manual For identification the model code A000 906 XX XX as well as the power supply ratings voltage frequency current indicat ed below it are especially relevant The following wallboxes are described in this manual Model Grid connection Model Variant A0009069206 see product label Fixed charging cable according to IEC 62196 2 Type 2 ca 6 m charging output 11 kW A0009069306 see pr...

Page 11: ...h LED may be illuminated continuous ON flash be extinguished continuous OFF You can find further information about operating states on the following pages Charging procedure with the smart Wallbox The wallbox is engineered for the fastest possible charging procedure of your smart vehicle according to IEC 61851 1 Mode 3 Actual charging time depends on the battery installed in the vehicle and its re...

Page 12: ...cal position Charging procedure unblocked PLEASE NOTE Unblocking is only required to start the charging procedure The key switch may be re turned to the horizontal position immediately afterwards and this will not interrupt the charging procedure However after separating the connection with the vehicle the next charging procedure is again blocked by the wallbox Operating status is shown by the LED...

Page 13: ...e has been either paused or completed Distinguishing these two op erating states is only possible by checking the battery charge indicator inside the vehicle Should the vehicle not be fully charged after a sufficiently long charging process please contact your local smart partner After the charging procedure has been completed please remove the cable from the vehicle socket and store it appropriat...

Page 14: ...ate the current charging procedure and reinitiate it to reset the error If the error repeats or occurs permanently take the wallbox out of op eration see page 11 and contact your local smart technical support When the red LED flashes every 10 seconds and the green LED also flashes every 2 seconds the wallbox is only providing reduced charging capacity If the error repeats or occurs permanently tak...

Page 15: ... Mode 3 charging cable and contact your local smart technical support The indicator LEDs show an er ror message The wallbox detects a malfunction Please reinitiate the charging procedure If the error repeats or occurs permanently take the wallbox out of operation see page 11 and contact your local smart technical support PLEASE NOTE Should the power supply be faulty please take the wallbox out of ...

Page 16: ...must be protected in the domestic power supply and at least one residual current circuit breaker Type A must be installed Always observe all local regulations for operating electrical devices which may prescribe a different residual current circuit breaker e g Type B Can the smart Wallbox be operated on a single phase power supply Yes in principle all wallbox model variants can be operated on a si...

Page 17: ...n the side of the box which is used to unblock the charging procedure are also included If both keys to the key switch have been lost and the key switch on the right side of the housing is in the horizontal position the wallbox is blocked for charging operations and no further charging proce dures are possible Contact the dealer from whom you have purchased the wallbox to order replace ment keys f...

Page 18: ...rol Customization internal RS485 interface no user access Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensation Class of protection I Overvoltage category III Degree of pollution 3 Degree of protection housing IP54 IP44 Impact strength IK08 Dimensions incl mounting plate 492 x 400 x 194 mm H x W x D Dimensions w o mounting plate 492 x 400 x 1...

Page 19: ...nd dimensions The smart Wallbox is delivered fully assembled and quality checked All dimensions are indicated in the scale drawings below Wallbox with fixed charging cable Plan and elevation all dimensions in mm 394 143 492 134 194 400 492 194 ...

Page 20: ... voltage directive ElektroG Electrical and Electronic Device Statute Device safety standards Standard Explanation IEC 61851 1 Ed 2 0 2010 Conductive charging systems for electric vehicles Part 1 General re quirements IEC TS 61439 7 2014 Part 7 Switching device combinations for specific applications such as marinas campgrounds market squares charging stations for electric vehicles DIN EN 61851 1 20...

Page 21: ...variant A0009069206 CE certification and compliance declaration The smart Wallbox carries the CE mark The associated declaration of compliance is avail able for download in electronic format at www yourwallbox de Maintenance After installation your wallbox is mostly maintenance free However because the wallbox processes high electrical voltages internally it is recommended to conduct a visual insp...

Page 22: ...third parties are without restriction subject to the regulations of the respectively applicable trademark law and the property rights of the respective registered owners All trademarks trading names or company names marked here as such are or may be trademarks or registered trademarks of their respective owners All rights not explicitly granted here are reserved The absence of explicit identificat...

Page 23: ...al and electronic devices are taken back by the manufacturer in order to have them properly disposed of or recycled Therefore devices marked with this symbol may not be disposed of as part of unsort ed domestic waste inside the European Union Please inquire with your local authori ties regarding proper disposal The materials are recyclable as marked By re using recycling or through other forms of ...

Page 24: ...art www smart com The manufacturer may have made minor technical modifications to the product after publication of this instruction manual This may also have led to minor discrepancies in the appearance of the product Any color differences are a result of the printing process ...

Reviews: