7.4
CROSSPOINT SELECTION
The front panel of the SDS-2500 can be used to change the crosspoint selections, this is only applicable when
the unit is in matrix mode. For control when in other modes please refer to Infra-Red or RS232 control sections
of this manual.
When in matrix mode the LCDs default display will show the 4 outputs, A-D along the top of the display and the
4 inputs they are currently switched to along the bottom of the display.
Changing inputs requires the use of the output and input buttons on the front of the SDS-2500.
To initiate a crosspoint change, press one of the output buttons. As an example we will change output B to
input 3. Firstly, press Output B button, B will flash on the LCD to show that output is now being controlled. The
output selected will continue to flash for five seconds, within this time you should press the input you wish to
switch to, in this example input 3. The LCD will then update to reflect the change.
The remaining outputs can be controlled in a similar fashion when a single crosspoint change is required.
If you wish to switch all four outputs to the same input you can utilise the ALL button. Press this button and all
four outputs A-D will flash for five seconds. Within this time you should press the input to which you want all
outputs switched. The LCD will update to show the change has been successful.