Appendix A
A.1
CERTIFICATIONS INFORMATIONS
European Directive Information
Authorized representative in European Community
Smar Gmbh-Rheingaustrasse 9-55545 Bad Kreuzanach
PED Directive (97/23/EC) – Pressure Equipment Directive
This product is in compliance with the directive and it was designed and manufactured in
accordance with sound engineering practice using several standards from ANSI, ASTM, DIN and
JIS.
EMC Directive (2004/108/EC) - Eletromagnetic Compatibility
The EMC test was performed according to IEC standard: IEC61326-1:2006, IEC61326-2-3:2006,
IEC61000-6-4:2006, IEC61000-6-2:2005. For use in environment only.
Keep the shield insulated at the instrument side, connecting the other one to the ground if
necessary to use shielded cable.
ATEX Directive (94/9/EC) – Equipment and protective systems intended for use in potentially
explosive atmospheres.
This product was certified according European Standards at NEMKO and EXAM (old DMT). The
certified body for manufacturing quality assessment is EXAM (number 0158).
LVD Directive 2006/95/EC – Electrical Equipment designed for use within certain voltage
limits
According the LVD directive Annex II the equipment under ATEX “Electrical equipment for use in an
explosive atmosphere” directive are excluded from scope from this directive.
The EC declarations of conformity for all applicable European directives for this product can be
found at
www.smar.com
.
Other Aprovals
FMEDA Report
Certifier Body: Exida
Failure Modes, Effects and Diagnostics Analysis (Report No. R02 / 11-19).
Hazardous Locations Certifications
NOTE
The IP68 sealing test (immersion) was performed at 1 bar for 24 hours. For any other situation,
please consult Smar.
North American Certifications
FM Approvals
Certificate N: FM 4B9A4.AX
Explosion-proof for Class I, Division 1, Groups A, B, C, and D;
Dust-ignition proof for Class II, Division 1, Groups E, F, and G; Class III, Division 1; hazardous
locations.
Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E,
F, and G; Class III, Division 1;
Non-incendive for Class I, Division 2, Groups A, B, C, and D
Entity parameters: V
max
= 30 Vdc I
max
= 110 mA Ci = 8nF Li = 0.24 mH
Ambient Temperature: (-40ºC < T
amb
<+60ºC).
Enclosure Type: 4X or Type 4.
CSA International (Canadian Standards Association)
Certificate N: CSA1111005
Class 2258 02 Hazardous Locations
for Class I, Division 1, Groups B, C and D; Class II, Division 1,
Groups E, F and G; Class III, Division 1; Class I, Division 2, Groups A, B, C and D; Class II, Division
2, Groups E, F and G; Class III.
Summary of Contents for LD291
Page 1: ...INTELLIGENT PRESSURE TRANSMITTER LD291 Version 6 MAR 12 L D 2 9 1 M E ...
Page 8: ...LD291 Operation and Maintenance Instruction Manual VIII ...
Page 11: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD291 Sanitary ...
Page 13: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD291 Level ...
Page 36: ...LD291 Operation and Maintenance Instruction manual 3 10 ...
Page 58: ...LD291 Operation and Maintenance Instruction Manual 5 12 ...
Page 70: ...LD291 Operation Maintenance Instruction Manual 6 12 ...
Page 74: ...LD291 Certifications Information A 4 NEMKO and DMT CEPEL ...
Page 76: ...LD291 Certifications Information A 6 CEPEL ...
Page 78: ...LD291 Certifications Information A 8 FM ...
Page 79: ...Appendix A A 9 NEMKO ...
Page 80: ...LD291 Certifications Information A 10 ...