Technical Characteristic
6.9
MODEL
LOW COST FLANGED PRESSURE TRANSMITTER (CONTINUATION)
COD.
Output Signal
G0
4-20 mA
COD.
Housing Material (11) (12)
H0
H1
H2
Aluminium (IP/TYPE)
316 SST (IP/TYPE)
Aluminium for saline atmosphere (IPW/TYPEX)
(10)
H3
H4
316 SST for saline atmosphere (IPW/TYPEX)
(10)
Copper Free Aluminium for Saline Atmosphere (IPW/TYPEX)
(10)
COD.
Identification Plate
I1
I2
I3
FM: XP, IS, NI, DI
NEMKO: Ex-d, Ex-ia
CSA: XP, IS, NI, DI
I4
I5
I6
EXAM (DMT): Ex-ia; NEMKO: Ex-d
CEPEL: Ex-d, Ex-ia
Without Certification
I7
IJ
EXAM (DMT) Grupo I, M1 Ex-ia
NEMKO: Ex-d
COD. Painting
P0
P3
P4
P5
Munsell N 6,5 Gray
Polyester Black
Epoxy White
Polyester Yellow
P6
P8
P9
PC
Epoxy Yellow
Without Painting
Blue Safety Base Epoxy – Eletrostatic Painting
Safety Base Polyester – Eletrostatic Painting
COD. Display Unit 1
Y0
Y1
Y2
Percentage
Current (mA)
Pressure (Eng. Unit)
Y3
YU
Temperature (Temperature)
Y
User’s specification
(9)
U
COD. Display Unit 2
Y0
Y4
Y5
Percentage
Current (mA)
Pressure (Eng. Unit)
Y6
YU
Temperature (Temperature)
Y
User’s specification
(9)
U
COD. Tag Plate
J0
J1
With TAG
Without TAG
J2
User’s specification
LD291L
G0
H0
I1
P0
Y0
Y5
J0
←
TYPICAL MODEL NUMBER
Optional Items
Special Procedures
C1
–Degrease Cleaning (Oxygen or Chlorine Service)
Burnout
BD
– Down Scale
BU
– Up Scale
Lower Housing
Connection
U0
– With 1 Flush Connection 1/4” NPT (if supplied with lower housing)
U1
–
With 2 Flush Connections 1/4” NPT per 180º
U2
–
With 2 Flush Connections 1/4” NPT per 90º
U3
–
With 2 Flush Connections 1/2” - 14 NPT per 180º (with cover)
U4
–
Without Flush Connection
NOTES
(1)
Silicone Oils not recommendations for Oxygen (O
2
) or Chlorine service.
(2)
Not applicable for vacuum service.
(3)
Certificate for use in Hazardous Locations (CEPEL, NEPSI, NEMKO, EXAM, FM, CSA).
(4)
Certificate for use in Hazardous Locations (CEPEL, CSA).
(5)
Certificate for use in Hazardous Locations (CEPEL, NEPSI, NEMKO, EXAM).
(6)
Attention, check corrosion rate for the process, tantalum plate 0.1 mm, AISI 316L extension 3 to 6mm.
(7)
Fluorolube fill fluid is not available for Monel diaphragm.
(8)
Inert Fluid: Safe for oxygen service.
(9)
Limited values to 4 1/2 digits; limited unit to 5 characters.
(10)
IPW/TYPEX was tested for 200 hours according to NBR 8094 / ASTM B 117 standard.
(11)
IPX8 tested for 10 meters of water column for 24 hours.
(12)
Ingress Protection:
Products
CEPEL
NEMKO/EXAM
FM
CSA
NEPSI
LD29X
IP66/W
IP66/68/W
Type 4X/6/6P
Type 4X
IP67
(13)
Not certified for use in hazardous locations.
Summary of Contents for LD291
Page 1: ...INTELLIGENT PRESSURE TRANSMITTER LD291 Version 6 MAR 12 L D 2 9 1 M E ...
Page 8: ...LD291 Operation and Maintenance Instruction Manual VIII ...
Page 11: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD291 Sanitary ...
Page 13: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD291 Level ...
Page 36: ...LD291 Operation and Maintenance Instruction manual 3 10 ...
Page 58: ...LD291 Operation and Maintenance Instruction Manual 5 12 ...
Page 70: ...LD291 Operation Maintenance Instruction Manual 6 12 ...
Page 74: ...LD291 Certifications Information A 4 NEMKO and DMT CEPEL ...
Page 76: ...LD291 Certifications Information A 6 CEPEL ...
Page 78: ...LD291 Certifications Information A 8 FM ...
Page 79: ...Appendix A A 9 NEMKO ...
Page 80: ...LD291 Certifications Information A 10 ...