background image

INSTALLATION INSTRUCTIONS

FOR EBF-625/EBF-655

SENSOR ACTIVATED FAUCETS

Code No: 9108237

rev. 3 (12/10)

O P T I M A   F A U C E T S

MODELS

EBF-625
EBF-655
Battery powered,
Sensor activated
lavatory Faucets

EBF-625

EBF-655

installation of the Sloan optima plus EBF-625 or EBF-655 Battery 
powered, Sensor activated Faucet makes wash-up totally “hands free” 
providing the ultimate in sanitary protection and automatic operation.
The optima plus faucet uses infrared technology to sense the user’s
presence and turn on a water supply that has been pre-mixed to the
desired water temperature. when the user’s hands are removed from
the invisible beam of light, the water supply automatically turns off. 
in addition, the faucet is powered by four (4) “C” batteries which 
eliminates the need to run any electrical lines to the system.

The Sloan EBF-625 or EBF-655 battery powered, sensor activated
faucet comes complete with an integral faucet and sensor assembly,

control module, alkaline batteries, and all mounting hardware. 
Bak-cheks and a grid strainer are also available as optional equipment. 
The installer should supply 3/8” copper supply tube or flexible hose
connections.

The following instructions serve as a guide when installing the Sloan
EBF-625 or EBF-655 faucet. as always, good safety practices and care
when installing your new faucet.

if further assistance is required, contact your nearest 

Sloan representative office or the Sloan installation

Engineering Department at 1-888-SloaN-14.

LIMITED WARRANTY

Sloan Valve Company warrants its EBF-625 and EBF-655 faucets to be made of first class materials, free from defects of material or workmanship under normal
use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of
three (3) years (one (1) year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or
parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. 
No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve
Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of batteries.

ThErE arE No warraNTiES whiCh ExTEND BEyoND ThE DESCripTioN oN ThE FaCE hErEoF. iN No EVENT iS SloaN ValVE CompaNy rESpoNSiBlE For aNy 
CoNSEquENTial DamagES oF aNy mEaSurE whaTSoEVEr.

Summary of Contents for Optima ETF-600

Page 1: ...f 15 VA of current rating for each solenoid valve used Refer to Step 4 Install Transformer for further information Mixing Valve When installing the faucet with a Sloan mixing valve these Installation...

Page 2: ...ASE GASKET Note Refer to the Installation Instructions included with the ETF 578 A Trim Plate for additional information about using an 8 Trim Plate with an ETF 600 faucet Apply thread sealant or Tefl...

Page 3: ...PLY SOLENOID VALVE 1 4 PIPE TO 3 8 TUBE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 BAK CHEK COMPRESSION TEE FOR APPLICATIONS USING DUAL WATER SUPPLY ETF 600 ETF 610 3 8 10 mm SUPPLY TUBE 3 8...

Page 4: ...ommended A Run wires from secondary side of Transformer to 3 8 inch 10 mm hole at back of Control Module Enclosure If necessary wires can be run through wall and then inserted through hole in back of...

Page 5: ...NAL BLOCK 2 INSERT POWER CABLES 3 SECURE WITH SCREWS 4 REINSTALL TERMINAL BLOCK CONNECTOR BOARD POWER CABLE MODULAR RECEPTACLE B Insert Solenoid Valve Connector into the Modular Receptacle on Connecto...

Page 6: ...3 Dip Switches as shown in Table 1 Table 1 Time Out Settings Unless otherwise specified all ETF 600 ETF 610 Faucets leave the factory set with a 30 second Time Out Note The position of Dip Switch 4 ra...

Page 7: ...ates BUT does NOT change to RED when hands are placed in the Sensor s detection zone CAUSE Sensor range is set too short SOLUTION Increase Sensor detection range CAUSE Sensor is faulty SOLUTION Replac...

Page 8: ...Strain Relief and Crimp Connectors Transformer to Control Module OPTIONAL TRIM PLATES 13A ETF 607 A 4 102 mm Centerset Single hole Trim Plate Kit for ETF 610 Faucet 13B ETF 608 A 8 203 mm Centerset S...

Page 9: ...supply lines or tempered water supply line Mixing Valve When installing the faucet with a Sloan Mixing Valve these Installation Instructions AND the Installation Instructions packaged with the Mixing...

Page 10: ...lves for Hot and Cold Water Supply shown with 4 trim Plate ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTE OPTIONA ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER...

Page 11: ...old supply stops Supply tubes and stops furnished by installer Install a 3 8 inch 10 mm copper supply tube between Bak Chek Compression Tee and inlet side of Solenoid Valve Tighten Compression Fitting...

Page 12: ...and Plastic Anchors A Install the Control Module in an appropriate location Control Module must be installed so that all cables enter from the bottom of the unit When installed Cables from the Spout a...

Page 13: ...ts are factory set to operate when hands are placed 4 to 5 inches 102 to 127 mm from Sensor This range should be satisfactory for most installations If range adjustment is required refer to the follow...

Page 14: ...ative finishes Use ONLY soap and water then wipe dry with clean cloth or towel While cleaning the bathroom tile the faucet should be protected from any splattering of cleaner Acids and cleaning fluids...

Page 15: ...Module SOLUTION Disconnect and reconnect Sensor Cable to the Control Module CAUSE Sensor range is set at minimum distance SOLUTION Increase Sensor range Refer to Step 9 Range Adjustment CAUSE Control...

Page 16: ...ludes Base Gasket Spacer Washer 9 16 Lockwasher 1 4 NPSM Hex Nut and ETF 547 Compression Fitting Connector 5 ETF 547 1 8 NPT Pipe to 3 8 Tube Compression Fitting Connector female 6 ETF 617 A 3 8 Bak C...

Page 17: ...ide when installing the Sloan EBF 625 or EBF 655 faucet as always good safety practices and care when installing your new faucet if further assistance is required contact your nearest Sloan representa...

Page 18: ...NG 3 8 COMPRESSION FITTING 3 8 COPPER SUPPLY TUBE NOT SUPPLIED 3 8 COPPER SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE EBF 655 FAUCET WITH SINGLE LINE WATER SUPPLY EBF 625 FAUCET WITH SINGLE LINE WATER SUP...

Page 19: ...hen connecting the faucet to a hot and cold water supply two Bak Cheks are required water temperature can be con trolled by adjusting the supply stops when connecting the faucet to a single line water...

Page 20: ...so that it faces sideways vertically however optimum performance is obtained when the control module is horizontal with the Sloan logo on the cover facing up install the control module in an appropri...

Page 21: ...UBE COMPRESSION FITTING 1 8 PIPE NIPPLE 3 8 SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE 3 8 TEE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 SOLENOID VALVE COMPRESSION FITTING TOP OUTLET 3 8 SOLEN...

Page 22: ...T The opTima plus EBF 625 and EBF 655 faucets are factory set to operate when hands are placed 4 5 102 127 mm from sensor This range should be satisfactory for most installations if range adjustment i...

Page 23: ...the faucet to purge any air from the system lines Check for leaks and repair as necessary OPERATION 1 a continuous invisible beam of infrared light is emitted from the sensor located on the throat of...

Page 24: ...plied to sensor Ensure that the batteries are installed properly Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment rei...