background image

3

A

Connect 3/8” O.D. Supply Tube between Compression Fitting on
outlet side of Solenoid Valve and Compression Fitting on Spout’s
Pipe Nipple or Water Supply Tube.

Note: Flow direction of Solenoid Valve is indicated by arrow on Valve Body.

3 - CONNECT SUPPLY LINE(S)

Note: Sloan Valve Company recommends that this faucet be installed with
our trim plate. Our trim plate includes an anti-rotation feature to prevent
rotary motion of this single-hole pedestal-style faucet.

SENSOR

CABLE

Apply thread sealant or Teflon tape to threads at end of Faucet
Water Supply Tube. Install 1/4" Pipe x 3/8” Tube Compression
Fitting on end of Faucet Water Supply Tube.

D

A

Slide Base Gasket over Faucet Water Supply Tube and Sensor
Cable. Install optional Trim Plate, then Trim Plate Gasket.

Holding Faucet Base Gasket and optional Trim Plate assembly in
place, insert Sensor Cable and Faucet Water Supply Tube through
the 1" (25 mm) center hole in deck or lavatory. Use plumber’s putty
to secure optional Trim Plate.

B

Thread Sensor Cable
through side of
Mounting Spacer.
Secure Faucet to
deck or lavatory using
Flat Washer,
Lockwasher and
Mounting Nut.

C

FAUCET

BASE

GASKET

MOUNTING

SPACER

FLAT

WASHER

LOCKWASHER

MOUNTING

NUT

1/4” NPT PIPE TO

3/8” TUBE

COMPRESSION

FITTING

1/4” NPT

WATER

SUPPLY TUBE

1/8” PIPE NIPPLE

SOLENOID VALVE

1/8” PIPE TO 3/8” TUBE

COMPRESSION FITTING

3/8” SUPPLY TUBE

(NOT SUPPLIED)

1/4” WATER

SUPPLY TUBE

3/8” BAK-CHEK

®

COMPRESSION TEE

(FOR APPLICATIONS USING

DUAL WATER SUPPLY)

SOLENOID VALVE

1/4” PIPE TO 3/8” TUBE

COMPRESSION FITTING

3/8” SUPPLY TUBE

(NOT SUPPLIED)

3/8” BAK-CHEK

®

COMPRESSION TEE

(FOR APPLICATIONS USING

DUAL WATER SUPPLY)

ETF-600

ETF-610

3/8” (10 mm)
SUPPLY TUBE

3/8” (10 mm)

COMPRESSION

FITTING

SOLENOID

VALVE

SUPPLY

STOP

B

For Single Line Water Supply Applications
Install a 3/8 inch (10 mm) copper supply
tube between the supply stop and inlet side
of Solenoid Valve. (Supply stop and copper
supply tube furnished by installer.) Tighten
Compression Fittings securely.

Important: Keep thread sealant out of your waterway and prevent

component part damage! Do not use sealant on compression fittings.
When thread sealant is used, do not apply it to the first two “starter”
threads.

Important: Flush dirt, debris, and sediment

from the supply line(s).

1B - INSTALL ETF-610 FAUCET

3/8” (10 mm)

COMPRESSION

FITTING

3/8” (10 mm)
SUPPLY TUBE

SOLENOID

VALVE

SUPPLY

STOP

For Dual Line Hot and Cold Water Supply
Applications
Install a 3/8 inch (10 mm) copper supply
tube between Bak-Chek

®

Compression

Tee and hot and cold supply stops.
(Supply stops and copper supply tube
furnished by installer.) Install a 3/8 inch
(10 mm) copper supply tube between
Bak-Chek

®

Compression Tee and inlet

side of Solenoid Valve. Tighten
Compression Fittings securely.

Note: Failure to install the Bak-Chek

®

Tee 

can result in a cross flow connection
when the faucet is off and the supply
stops are open. If pressure of the 
hot and cold water supply differ, hot 
water can migrate into the cold water
supply or vice-versa. Most plumbing
codes require that the Bak-Chek

®

be used

to prevent this.

A

2 - INSTALL SOLENOID VALVE

3/8” (10 mm) 

BAK-CHEK

®

TEE

USED ON DUAL
WATER SUPPLY

APPLICATIONS

ONLY

Summary of Contents for Optima ETF-600

Page 1: ...f 15 VA of current rating for each solenoid valve used Refer to Step 4 Install Transformer for further information Mixing Valve When installing the faucet with a Sloan mixing valve these Installation...

Page 2: ...ASE GASKET Note Refer to the Installation Instructions included with the ETF 578 A Trim Plate for additional information about using an 8 Trim Plate with an ETF 600 faucet Apply thread sealant or Tefl...

Page 3: ...PLY SOLENOID VALVE 1 4 PIPE TO 3 8 TUBE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 BAK CHEK COMPRESSION TEE FOR APPLICATIONS USING DUAL WATER SUPPLY ETF 600 ETF 610 3 8 10 mm SUPPLY TUBE 3 8...

Page 4: ...ommended A Run wires from secondary side of Transformer to 3 8 inch 10 mm hole at back of Control Module Enclosure If necessary wires can be run through wall and then inserted through hole in back of...

Page 5: ...NAL BLOCK 2 INSERT POWER CABLES 3 SECURE WITH SCREWS 4 REINSTALL TERMINAL BLOCK CONNECTOR BOARD POWER CABLE MODULAR RECEPTACLE B Insert Solenoid Valve Connector into the Modular Receptacle on Connecto...

Page 6: ...3 Dip Switches as shown in Table 1 Table 1 Time Out Settings Unless otherwise specified all ETF 600 ETF 610 Faucets leave the factory set with a 30 second Time Out Note The position of Dip Switch 4 ra...

Page 7: ...ates BUT does NOT change to RED when hands are placed in the Sensor s detection zone CAUSE Sensor range is set too short SOLUTION Increase Sensor detection range CAUSE Sensor is faulty SOLUTION Replac...

Page 8: ...Strain Relief and Crimp Connectors Transformer to Control Module OPTIONAL TRIM PLATES 13A ETF 607 A 4 102 mm Centerset Single hole Trim Plate Kit for ETF 610 Faucet 13B ETF 608 A 8 203 mm Centerset S...

Page 9: ...supply lines or tempered water supply line Mixing Valve When installing the faucet with a Sloan Mixing Valve these Installation Instructions AND the Installation Instructions packaged with the Mixing...

Page 10: ...lves for Hot and Cold Water Supply shown with 4 trim Plate ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTE OPTIONA ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER...

Page 11: ...old supply stops Supply tubes and stops furnished by installer Install a 3 8 inch 10 mm copper supply tube between Bak Chek Compression Tee and inlet side of Solenoid Valve Tighten Compression Fitting...

Page 12: ...and Plastic Anchors A Install the Control Module in an appropriate location Control Module must be installed so that all cables enter from the bottom of the unit When installed Cables from the Spout a...

Page 13: ...ts are factory set to operate when hands are placed 4 to 5 inches 102 to 127 mm from Sensor This range should be satisfactory for most installations If range adjustment is required refer to the follow...

Page 14: ...ative finishes Use ONLY soap and water then wipe dry with clean cloth or towel While cleaning the bathroom tile the faucet should be protected from any splattering of cleaner Acids and cleaning fluids...

Page 15: ...Module SOLUTION Disconnect and reconnect Sensor Cable to the Control Module CAUSE Sensor range is set at minimum distance SOLUTION Increase Sensor range Refer to Step 9 Range Adjustment CAUSE Control...

Page 16: ...ludes Base Gasket Spacer Washer 9 16 Lockwasher 1 4 NPSM Hex Nut and ETF 547 Compression Fitting Connector 5 ETF 547 1 8 NPT Pipe to 3 8 Tube Compression Fitting Connector female 6 ETF 617 A 3 8 Bak C...

Page 17: ...ide when installing the Sloan EBF 625 or EBF 655 faucet as always good safety practices and care when installing your new faucet if further assistance is required contact your nearest Sloan representa...

Page 18: ...NG 3 8 COMPRESSION FITTING 3 8 COPPER SUPPLY TUBE NOT SUPPLIED 3 8 COPPER SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE EBF 655 FAUCET WITH SINGLE LINE WATER SUPPLY EBF 625 FAUCET WITH SINGLE LINE WATER SUP...

Page 19: ...hen connecting the faucet to a hot and cold water supply two Bak Cheks are required water temperature can be con trolled by adjusting the supply stops when connecting the faucet to a single line water...

Page 20: ...so that it faces sideways vertically however optimum performance is obtained when the control module is horizontal with the Sloan logo on the cover facing up install the control module in an appropri...

Page 21: ...UBE COMPRESSION FITTING 1 8 PIPE NIPPLE 3 8 SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE 3 8 TEE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 SOLENOID VALVE COMPRESSION FITTING TOP OUTLET 3 8 SOLEN...

Page 22: ...T The opTima plus EBF 625 and EBF 655 faucets are factory set to operate when hands are placed 4 5 102 127 mm from sensor This range should be satisfactory for most installations if range adjustment i...

Page 23: ...the faucet to purge any air from the system lines Check for leaks and repair as necessary OPERATION 1 a continuous invisible beam of infrared light is emitted from the sensor located on the throat of...

Page 24: ...plied to sensor Ensure that the batteries are installed properly Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment rei...