3
A
Connect 3/8” O.D. Supply Tube between Compression Fitting on
outlet side of Solenoid Valve and Compression Fitting on Spout’s
Pipe Nipple or Water Supply Tube.
Note: Flow direction of Solenoid Valve is indicated by arrow on Valve Body.
3 - CONNECT SUPPLY LINE(S)
Note: Sloan Valve Company recommends that this faucet be installed with
our trim plate. Our trim plate includes an anti-rotation feature to prevent
rotary motion of this single-hole pedestal-style faucet.
SENSOR
CABLE
Apply thread sealant or Teflon tape to threads at end of Faucet
Water Supply Tube. Install 1/4" Pipe x 3/8” Tube Compression
Fitting on end of Faucet Water Supply Tube.
D
A
Slide Base Gasket over Faucet Water Supply Tube and Sensor
Cable. Install optional Trim Plate, then Trim Plate Gasket.
Holding Faucet Base Gasket and optional Trim Plate assembly in
place, insert Sensor Cable and Faucet Water Supply Tube through
the 1" (25 mm) center hole in deck or lavatory. Use plumber’s putty
to secure optional Trim Plate.
B
Thread Sensor Cable
through side of
Mounting Spacer.
Secure Faucet to
deck or lavatory using
Flat Washer,
Lockwasher and
Mounting Nut.
C
FAUCET
BASE
GASKET
MOUNTING
SPACER
FLAT
WASHER
LOCKWASHER
MOUNTING
NUT
1/4” NPT PIPE TO
3/8” TUBE
COMPRESSION
FITTING
1/4” NPT
WATER
SUPPLY TUBE
1/8” PIPE NIPPLE
SOLENOID VALVE
1/8” PIPE TO 3/8” TUBE
COMPRESSION FITTING
3/8” SUPPLY TUBE
(NOT SUPPLIED)
1/4” WATER
SUPPLY TUBE
3/8” BAK-CHEK
®
COMPRESSION TEE
(FOR APPLICATIONS USING
DUAL WATER SUPPLY)
SOLENOID VALVE
1/4” PIPE TO 3/8” TUBE
COMPRESSION FITTING
3/8” SUPPLY TUBE
(NOT SUPPLIED)
3/8” BAK-CHEK
®
COMPRESSION TEE
(FOR APPLICATIONS USING
DUAL WATER SUPPLY)
ETF-600
ETF-610
3/8” (10 mm)
SUPPLY TUBE
3/8” (10 mm)
COMPRESSION
FITTING
SOLENOID
VALVE
SUPPLY
STOP
B
For Single Line Water Supply Applications
Install a 3/8 inch (10 mm) copper supply
tube between the supply stop and inlet side
of Solenoid Valve. (Supply stop and copper
supply tube furnished by installer.) Tighten
Compression Fittings securely.
Important: Keep thread sealant out of your waterway and prevent
component part damage! Do not use sealant on compression fittings.
When thread sealant is used, do not apply it to the first two “starter”
threads.
Important: Flush dirt, debris, and sediment
from the supply line(s).
1B - INSTALL ETF-610 FAUCET
3/8” (10 mm)
COMPRESSION
FITTING
3/8” (10 mm)
SUPPLY TUBE
SOLENOID
VALVE
SUPPLY
STOP
For Dual Line Hot and Cold Water Supply
Applications
Install a 3/8 inch (10 mm) copper supply
tube between Bak-Chek
®
Compression
Tee and hot and cold supply stops.
(Supply stops and copper supply tube
furnished by installer.) Install a 3/8 inch
(10 mm) copper supply tube between
Bak-Chek
®
Compression Tee and inlet
side of Solenoid Valve. Tighten
Compression Fittings securely.
Note: Failure to install the Bak-Chek
®
Tee
can result in a cross flow connection
when the faucet is off and the supply
stops are open. If pressure of the
hot and cold water supply differ, hot
water can migrate into the cold water
supply or vice-versa. Most plumbing
codes require that the Bak-Chek
®
be used
to prevent this.
A
2 - INSTALL SOLENOID VALVE
3/8” (10 mm)
BAK-CHEK
®
TEE
USED ON DUAL
WATER SUPPLY
APPLICATIONS
ONLY