background image

SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131

Phone: 1-800-982-5839 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380

www.sloanvalve.com

Copyright © 2010 SLOAN VALVE COMPANY

Rev. 2 (08/10)

ETF-600

1A

4A

ETF-610

4B

2

1B

2

5A

5B

7

12

11

10

9

6

13B

13A

15

14

16

Item

Part

Description

No.

No.

1A

ETF-543-A

Faucet Spout and Sensor Assembly (ETF-600)

1B

ETF-570-A

Pedestal Faucet Spout and Sensor Assembly (ETF-610)

2

ETF-1023-A 0.5 gpm (1.9 Lpm) Spray Head with Key (male thread)
ETF-1024-A 2.2 gpm (8.3 Lpm) Aerator Spray Head with Key (male thread)
ETF-1029-A 2.2 gpm (8.3 Lpm) Laminar Flow Spray Head (male thread)

3

ETF-435

Replacement Key Only for ETF-1023-A Spray Head and
ETF-1024-A Aerator Spray Head

4A

ETF-546-A

Faucet Mounting Kit for ETF-600 includes: Base Gasket, two (2)
Slotted Mounting Washers, two (2) Wing Nuts, and ETF-547
Compression Fitting Connector

4B

EBF-123-A

Faucet Mounting Kit for ETF-610 includes: Spacer, Base Gasket,
1/4” NPSM Hex Nut, Washer, 9/16” Lockwasher, Compression
Fitting Connector

5A

ETF-547

1/8” NPT Pipe to 3/8” Tube Compression Fitting Connector
(ETF-600)

5B

EBF-129

1/4” NPT Pipe to 3/8” Tube Compression Fitting Connector
(ETF-610)

6

ETF-617-A

3/8” Bak-Chek

®

Tee Compression Fitting

7

ETF-370-A

24 VAC Solenoid Valve Assembly, includes Wire Harness

8

ETF-437-A

Assembly Kit, includes: Compression Fittings (2), Compression Nut
(1), Compression Sleeve (1)

9

ETF-450-A

Control Module Assembly

10

ETF-233

Plug-In Transformer

11

EL-248-40

Box Mount Transformer

12

ETF-458-A

Power Cable with Strain Relief and Crimp Connectors (Transformer
to Control Module)

OPTIONAL TRIM PLATES

13A

ETF-607-A

4” (102 mm) Centerset Single-hole Trim Plate Kit for ETF-610
Faucet

13B

ETF-608-A

8” (203 mm) Centerset Single-hole Trim Plate Kit for ETF-610
Faucet

MIX-102-A

4” (102 mm) Centerset Double-hole Trim Plate Kit for ETF-610
Faucet with Optional Mixing Valve

MIX-106-A

8” (203 mm) Centerset Double-hole Trim Plate Kit for ETF-610
Faucet with Optional Mixing Valve

ETF-578-A

8” (203 mm) Centerset Single-hole Trim Plate Kit for ETF-600
Faucet

ETF-577-A

8” (203 mm) Centerset Double-hole Trim Plate Kit for ETF-600
Faucet with Optional Mixing Valve

3

3

Item

Part

Description

No.

No.

OPTIONAL MIXING VALVES

14

MIX-60-A

Below Deck Mechanical Water Mixing Valve (BDM Variation)

15

MIX-135-A

Below Deck Thermostatic Water Mixing Valve (BDT Variation)

16

MIX-110-AA Optimix

®

Deck Mounted Water Mixing Valve (ADM Variation) 

(only available for ETF-610 faucet)

FAUCET CABLE EXTENSION CORDS

Faucet to Control Module

Solenoid to Control Module

ETF-1005-26

26” (0.7 meter) Length

ETF-1003-36 36” (0.9 meter) Length

ETF-1005-36

36” (0.9 meter) Length

ETF-1003-48 48” (1.2 meter) Length

ETF-1005-72

72” (1.8 meter) Length

ETF-1003-72 72” (1.8 meter) Length

ETF-1005-108 108” (2.7 meter) Length

ETF-1003-108108” (2.7 meter) Length

SOLENOID VALVE REPAIR KIT

ETF-1009-A Includes replacement Filter

For additional information about Sloan Mixing Valves or Trim Plates, consult our
Installation Instructions and Maintenance Guides.

If further assistance is required, please contact the Sloan Valve Company Installation
Engineering Department at:

1-888-SLOAN-14 (1-888-756-2614)

The information contained in this document is subject to change without notice.

8

8

PARTS LIST

Summary of Contents for Optima ETF-600

Page 1: ...f 15 VA of current rating for each solenoid valve used Refer to Step 4 Install Transformer for further information Mixing Valve When installing the faucet with a Sloan mixing valve these Installation...

Page 2: ...ASE GASKET Note Refer to the Installation Instructions included with the ETF 578 A Trim Plate for additional information about using an 8 Trim Plate with an ETF 600 faucet Apply thread sealant or Tefl...

Page 3: ...PLY SOLENOID VALVE 1 4 PIPE TO 3 8 TUBE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 BAK CHEK COMPRESSION TEE FOR APPLICATIONS USING DUAL WATER SUPPLY ETF 600 ETF 610 3 8 10 mm SUPPLY TUBE 3 8...

Page 4: ...ommended A Run wires from secondary side of Transformer to 3 8 inch 10 mm hole at back of Control Module Enclosure If necessary wires can be run through wall and then inserted through hole in back of...

Page 5: ...NAL BLOCK 2 INSERT POWER CABLES 3 SECURE WITH SCREWS 4 REINSTALL TERMINAL BLOCK CONNECTOR BOARD POWER CABLE MODULAR RECEPTACLE B Insert Solenoid Valve Connector into the Modular Receptacle on Connecto...

Page 6: ...3 Dip Switches as shown in Table 1 Table 1 Time Out Settings Unless otherwise specified all ETF 600 ETF 610 Faucets leave the factory set with a 30 second Time Out Note The position of Dip Switch 4 ra...

Page 7: ...ates BUT does NOT change to RED when hands are placed in the Sensor s detection zone CAUSE Sensor range is set too short SOLUTION Increase Sensor detection range CAUSE Sensor is faulty SOLUTION Replac...

Page 8: ...Strain Relief and Crimp Connectors Transformer to Control Module OPTIONAL TRIM PLATES 13A ETF 607 A 4 102 mm Centerset Single hole Trim Plate Kit for ETF 610 Faucet 13B ETF 608 A 8 203 mm Centerset S...

Page 9: ...supply lines or tempered water supply line Mixing Valve When installing the faucet with a Sloan Mixing Valve these Installation Instructions AND the Installation Instructions packaged with the Mixing...

Page 10: ...lves for Hot and Cold Water Supply shown with 4 trim Plate ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTE OPTIONA ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER OPTIONAL ADAPTER...

Page 11: ...old supply stops Supply tubes and stops furnished by installer Install a 3 8 inch 10 mm copper supply tube between Bak Chek Compression Tee and inlet side of Solenoid Valve Tighten Compression Fitting...

Page 12: ...and Plastic Anchors A Install the Control Module in an appropriate location Control Module must be installed so that all cables enter from the bottom of the unit When installed Cables from the Spout a...

Page 13: ...ts are factory set to operate when hands are placed 4 to 5 inches 102 to 127 mm from Sensor This range should be satisfactory for most installations If range adjustment is required refer to the follow...

Page 14: ...ative finishes Use ONLY soap and water then wipe dry with clean cloth or towel While cleaning the bathroom tile the faucet should be protected from any splattering of cleaner Acids and cleaning fluids...

Page 15: ...Module SOLUTION Disconnect and reconnect Sensor Cable to the Control Module CAUSE Sensor range is set at minimum distance SOLUTION Increase Sensor range Refer to Step 9 Range Adjustment CAUSE Control...

Page 16: ...ludes Base Gasket Spacer Washer 9 16 Lockwasher 1 4 NPSM Hex Nut and ETF 547 Compression Fitting Connector 5 ETF 547 1 8 NPT Pipe to 3 8 Tube Compression Fitting Connector female 6 ETF 617 A 3 8 Bak C...

Page 17: ...ide when installing the Sloan EBF 625 or EBF 655 faucet as always good safety practices and care when installing your new faucet if further assistance is required contact your nearest Sloan representa...

Page 18: ...NG 3 8 COMPRESSION FITTING 3 8 COPPER SUPPLY TUBE NOT SUPPLIED 3 8 COPPER SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE EBF 655 FAUCET WITH SINGLE LINE WATER SUPPLY EBF 625 FAUCET WITH SINGLE LINE WATER SUP...

Page 19: ...hen connecting the faucet to a hot and cold water supply two Bak Cheks are required water temperature can be con trolled by adjusting the supply stops when connecting the faucet to a single line water...

Page 20: ...so that it faces sideways vertically however optimum performance is obtained when the control module is horizontal with the Sloan logo on the cover facing up install the control module in an appropri...

Page 21: ...UBE COMPRESSION FITTING 1 8 PIPE NIPPLE 3 8 SUPPLY TUBE NOT SUPPLIED SOLENOID VALVE 3 8 TEE COMPRESSION FITTING 3 8 SUPPLY TUBE NOT SUPPLIED 3 8 SOLENOID VALVE COMPRESSION FITTING TOP OUTLET 3 8 SOLEN...

Page 22: ...T The opTima plus EBF 625 and EBF 655 faucets are factory set to operate when hands are placed 4 5 102 127 mm from sensor This range should be satisfactory for most installations if range adjustment i...

Page 23: ...the faucet to purge any air from the system lines Check for leaks and repair as necessary OPERATION 1 a continuous invisible beam of infrared light is emitted from the sensor located on the throat of...

Page 24: ...plied to sensor Ensure that the batteries are installed properly Check that the orientation of each battery matches the positive and negative symbols shown on the bottom of the battery compartment rei...

Reviews: