6.4 Programming the Output Clock Format
The following tables provide the method to fully define every driver.
Table 6.7. Driver Set Up Options
Driver
Register Field
Description
Driver for output OUTx
OUTx_mode
Software interpreted driver configuration. See
OUTx _skew
Skew control. Programmed as an unsigned integer. Can add de-
lay of 35 ps/step up to 280 ps.
OUTx _stop_highz
Driver output state when stopped.
0 = low-z
1 = high-z
OUTx _cmos_inv
Sets the polarity of the two outputs in dual CMOS mode
0 = no inversion
1 = OUTx~ inverted
OUTx _cmos_slew
Controls CMOS slew rate from fast to slow.
00 = fastest
01 = slow
10 = slower
11 = slowest
OUTx _cmos_str
CMOS output impedance control.
0 = 50 Ω
1 = 25 Ω
Table 6.8. Driver Mode Options
drvxy_MODE
Driver Mode
0
off
1
CMOS on positive output only
2
CMOS on negative output only
3
dual CMOS outputs
4
2.5 V/3.3 V LVDS
5
1.8 V LVDS
6
2.5 V/3.3 V LVDS fast
7
1.8 V LVDS fast
8
HCSL 50 Ω (external termination)
9
HCSL 50 Ω (internal termination)
10
HCSL 42.5 Ω (external termination)
11
HCSL 42.5 Ω (internal termination)
12
LVPECL
Si5332-AM1/2/3 Automotive Grade Device Reference Manual • Programming the Volatile Memory (Registers)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
25
Rev. 0.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021