Register Field Name
Address
Base
Bit
Length
R/W/RW
Description
Device
Mode
OUT11_STOP_HIGHZ
B4
0
1
RW
Driver output state when stopped.
0 = low-Z
1 = high-Z
READY
OUT11_CMOS_INV
B4
4
2
RW
Sets the polarity of the two outputs in dual
CMOS mode.
0 = no inversion
1 = OUT11b inverted
READY
OUT11_DIFF_INV
B4
6
1
RW
Enalbles the
start_stop
up resistor on the
clk_m
pad.
READY
OUT11_CMOS_SLEW
B5
0
1
RW
Controls CMOS slew rate from fast to slow.
00 = fastest
01 = slow
10 = slower
11 = slowest
READY
OUT11_CMOS_STR
B5
2
1
RW
CMOS output impedance control.
0 = 50 Ω
1 = 25 Ω
READY
OUT5_OE
B6
5
1
RW
Output enable control for OUT5
READY/
ACTIVE
OUT4_OE
B6
4
1
RW
Output enable control for OUT4
READY/
ACTIVE
OUT3_OE
B6
3
1
RW
Output enable control for OUT3
READY/
ACTIVE
OUT7_OE
B6
7
1
RW
Output enable control for OUT7
READY/
ACTIVE
OUT6_OE
B6
6
1
RW
Output enable control for OUT6
READY/
ACTIVE
OUT0_OE
B6
0
1
RW
Output enable control for OUT0
READY/
ACTIVE
OUT2_OE
B6
2
1
RW
Output enable control for OUT2
READY/
ACTIVE
OUT1_OE
B6
1
1
RW
Output enable control for OUT1
READY/
ACTIVE
OUT10_OE
B7
2
1
RW
Output enable control for OUT10
READY/
ACTIVE
OUT9_OE
B7
1
1
RW
Output enable control for OUT9
READY/
ACTIVE
OUT8_OE
B7
0
1
RW
Output enable control for OUT8
READY/
ACTIVE
OUT11_OE
B7
3
1
RW
Output enable control for OUT11
READY/
ACTIVE
Si5332-AM1/2/3 Automotive Grade Device Reference Manual • Si5332 48-QFN Specific Registers
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
60
Rev. 0.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
60