55
SJ9233 RT, SJ9243 RT, SJ9253 RT, SJ9664 RT
221491AFA
Function tests
Section 4 – Inspections Before Operation
4.3-17 Do a test of the generator (optional
equipment)
1.
Use the MEWP ladder to enter the platform.
2.
Start the engine. Refer to
Figure 06
.
3.
Move the
generator
switch
9
to the on
position.
▪
Result:
The engine speed automatically
changes to high throttle. The generator starts.
The light goes on.
4.
Move the
generator
switch
9
to the off position.
▪
Result:
The generator stops. The light goes off.
The throttle goes back to idle.
4.3-18 Do a test of the SGLE switch
(optional equipment)
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
1.
Start the engine. Refer to
Figure 06
.
2.
Move the
lift/off/drive
switch
3
to the
lift
position
3b
.
3.
Do not squeeze the
function-enable
switch
4
or push the
SGLE
button
10
. Push and pull the
controller handle
5
to raise and lower the
platform.
▪
Result:
The platform does not raise or lower.
TM
4
5
9
3
3b
10
Summary of Contents for SJ9233 RT
Page 4: ...4 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 14: ...14 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 20: ...20 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 34: ...34 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 60: ...60 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 88: ...88 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 118: ...118 221491AFA SJ9233 RT SJ9243 RT SJ9253 RT SJ9664 RT Notes...
Page 121: ......
Page 122: ...www skyjack com www skyjack com...