SJ 63AJ
December 2007
Page 53
Section 3 - Operation
Start Operation
3.8-9
To Operate Using Emergency Power
Switch at Base Control Console
This is a momentary-type switch. This switch allows
all functions except the drive function to operate in the
event of engine malfunction. Refer to
Section 2.6
for the
emergency lowering procedure.
3.8-10
To Activate Platform Control Console
1.
In engine compartment, turn main power
disconnect switch to “ ” on position.
2.
On base control console, turn off/base/platform
(base/off/platform) key switch to “
” platform
position.
3.
On base control console, pull out “
” emergency
stop button.
WARNING
Ensure that you maintain three points of
contact to mount/dismount the platform.
WARNING
DO NOT
operate any control on operator’s
control console without proper fall
protection secured to the designated
location in the platform. Failure to avoid
this hazard could result in death or
serious injury.
4.
Enter platform and close gate.
5.
Attach body harness lanyards of each occupant
to platform lanyard rings.
6.
On platform control console, pull out “
”
emergency stop button.
7.
Push and hold “
” start position from start/on/off
switch until engine starts.
WARNING
DO NOT
over crank the starter. If engine
fails to start after multiple attempts,
contact a Service Technician.
NOTE
Engine will not start if you are pressing
down on the footswitch.
8.
Select desired engine RPM using throttle switch:
“
” high or “
” low.
WARNING
•
DO NOT
drive or steer the MEWP when the
platform position does not allow you a clear
view of the base.
• Your area of operation should be cordoned
from other personnel or equipment.