SJ 63AJ
December 2007
Page 31
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the aerial platform.
F
AMILIARIZA
TION
• Test Base Emergency Stop
1. Push in “
” emergency stop button.
Result:
Engine should shut down and
MEWP functions should not operate.
2. Pull out “
” emergency stop button and
restart engine.
• Test Function Enable Switch and All Boom
Functions
WARNING
Ensure that there are no personnel or
obstructions in test area and there is
sufficient room for boom to swing.
1. Do not hold “
” function enable switch.
Attempt to activate each boom and
platform switch.
Result:
All boom and platform functions
should not operate.
2. Hold “
” function enable switch and
activate each boom and platform function.
Result:
All boom and platform functions
should operate as selected.
• Test Platform Self-leveling
1. Lower boom to stowed position.
2. Adjust platform to a level position using
platform leveling switch.
3. Raise “
” and lower “
” main
boom through a full cycle.
Result:
Platform should remain level at all
times.
• Test Emergency Power
1. On base control console, push in “
”
emergency stop button to turn engine off.
2. On platform control console, push in “
”
emergency stop button.
CAUTION
When operating on auxiliary power, do
not operate more than one function
at a time to avoid overloading 12-Volt
auxiliary pump motor.
Base Control Console
HOUR METER
QUARTZ
COUNTER
Off/Base/Platform
Key Switch
Emergency
Stop
HOUR METER
QUARTZ
COUNTER
Base/Off/Platform
Key Switch
Emergency
Stop
Start/Function
Enable/
Emergency
Power Switch
Section 2 - Familiarization
Function Tests