Page 24
December 2007
SJ 63AJ
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the aerial platform.
F
AMILIARIZA
TION
2.3-6 Control Compartment
-
Ensure all compartment latches are
secure and in proper working order.
• Base Control Console
-
Ensure all switches are returned to their
neutral positions.
-
Ensure there are no loose or missing
parts and there is no visible damage.
• Hydraulic Tank
-
Ensure hydraulic filler cap is secure.
-
Ensure tank shows no visible damage
and no evidence of hydraulic leakage.
• Hydraulic Oil
-
Be sure that the boom is in the stowed
position, and then visually inspect the
sight gauge located on the front of the
hydraulic oil tank.
-
The hydraulic oil level should be between
the minimum and maximum marks on
the sight glass. Add oil as needed. Refer
to
Table 4.2b
for recommended oil type.
• Brake and Main Manifolds
-
Ensure all fittings and hoses are properly
tightened and there is no evidence of
hydraulic leakage.
-
Ensure there are no loose wires or
missing fasteners.
• Emergency Power Unit
-
Ensure there are no loose or missing
parts and there is no visible damage.
-
Ensure there are no loose wires or
missing fasteners.
-
Ensure all fittings and hoses are properly
tightened and there is no evidence of
hydraulic leakage.
• Fuel Tank
IMPORTANT
Before using your MEWP ensure there
is enough fuel for expected use.
-
Ensure fuel filler cap is secure.
-
Ensure tank shows no visible damage
and no evidence of fuel leakage.
Hydraulic Tank
Main Manifold
Brake Manifold
Base Control
Console
Fuel Tank
Emergency
Power Unit
Visual & Maintenance Inspection