Page 34
December 2007
SJ 63AJ
It is the responsibility of the operator to read, completely understand and follow all instructions and warnings
contained in this operating manual and on the aerial platform.
F
AMILIARIZA
TION
• Test Platform Emergency Stop
1. Start engine by selecting “
” start
position from engine start/on/off switch.
Result:
Engine should start.
2. Push in “
” emergency stop button.
Result:
Engine should shut down and
MEWP functions should not operate.
• Test Footswitch
1. Pull out “
” emergency stop button.
2. Ensure engine start/on/off switch is in
“
” on position.
3. Do not start engine.
4. Select generator on/off switch to off
position (if equipped).
5. Depress and hold footswitch and attempt
to start engine by selecting “
” start
position from engine start/on/off switch.
Result:
Engine should not start.
6. Without depressing footswitch, try to start
engine.
Result:
Engine should start.
7. W i t h e n g i n e r u n n i n g a n d w i t h o u t
depressing footswitch, test each boom
and platform function.
Result:
MEWP functions should not
operate.
NOTE
A
15-second
anti-tiedown
feature
deactivates footswitch when operator
depresses it for 15 seconds without
activating any function.
Platform Control
Console
Footswitch
Emergency Stop
Drive/Steer
Controller
Tie-off Point
Tie-off Point
Function Tests
Section 2 - Familiarization