26
EN
min
h
On
End of programming
Programming has been completed. To adopt the
values set the programming has to be confirmed
with the green key 3.3 (see Fig. 13) within 30
seconds.
min
h
On
Normally closed contact
Output signal is preset as normally closed con-
tact. Programming step P4
min
h
On
Normally open contact
Output signal is preset as normally open contact.
Programming step P4
min
h
On
Fault - low-level signal
No differentiation between fault and low-level
signal. Programming step P5
min
h
On
Output signal programmed as normally open
contact
Intermittent low-level signal, functional faults as
permanent signal (ON). Programming step P5
min
h
On
Output signal programmed as normally closed
contact
Intermittent low-level signal, functional faults as
permanent signal (OFF). Programming step P5
min
h
On
Start stage SP
When being switched on the pump starts with a
pause time. Programming step P6
min
h
On
Start stage SO
When being switched on the pump starts with
the lubrication time. Programming step P6
Remaining pause time
Consists of 3 consecutive displays that change in
a two second interval.
Display 1
Display 2
Shows the remaining pause time in hours.
Display 3
Shows the remaining pause time in minutes.
Example: 0110. Remaining pause time
1 hour and 10 minutes.
min
h
On
min
h
On
min
h
On
3. Overview, functional description