30
EN
Programming step/ value
Factory setting
Setting range
P1 Pause time in hours
6 hours
0-59 hours
P2 Pause time in minutes
0 minutes
0-59 minutes
P3 Metering device cycles per operating cycle
1 cycle
V DC pumps 1-5 cycles
V AC pumps 1-3 cycles
#
P4 Signal output fault relay
no
NO contact / NC contact
P5 Differentiation of low-level signal and fault signal
--
-- (no differentiation)
-U (output signal as nc contact)
-Π (output signal as no contact)
P6 Start stage
SP
[SP] Pump starts with pause time
[SO] Pump starts with lubrication time
Maximum runtime
30 minutes
not modifiable
Maxmum adjustable pause time = 59 hours 59 minutes
Minimum adjustable pause time V DC pump = 4 minutes
Minimum adjustable pause time V AC pump = 20 minutes
#
For the AC versions adhere to the following value in order to avoid pump failure due to exceeding the max. runtime:
mximum of 3 cycles
4.3 Factory settings of pumps
4. Technical data