Normal operation
The SKF control unit must be connected to mains electricity. It is operated by a SKF
operating element (see
Please note: Excessive current consumption, unusual noises or an independent
downward movement indicate a damaged pillar. The TFG must not be run any
more. Immediately inform the manufacturer that performs the inspection.
Emergency shutdown for TFG 1..
1
Pull the control unit mains cable from the socket.
Emergency shutdown for TFG 5.., TFG 9..
1
Pull pillar's mains cable from the socket.
Please note: The TFG telescopic pillar does not have an on / off switch and must
be disconnected from the power supply. Only this measure will de-energize the
TFG.
Please note: The entity doing the further processing must devise and install an
emergency stop switch or a separation from the mains supply on all poles.
CAUTION
Beware of electric shock due to a squashed cable. Ensure that ca-
bles cannot get pinched or damaged. Check that the mains voltage
corresponds to the nominal value on the type plate. Ensure that the
strain relief clamp and cabling are correct.
CAUTION
Beware of damage to the TFG caused by splashing or hose-directed
water. The telescopic pillar TFG is, in accordance with IP30, not
protected against splashing or hose-directed water. Exposure of
the TFG to splashing or hose directed water must be prevented at
all times.
•
If required, protect your telescopic pillar with appropriate
protective measures.
!
!