6.4 Changing the metering volume
internally
6.4.1 SSV, SSV-E, SSVL and SSVM
metering devices
Closing unneeded outlets with closure
screws (3) increases the output of the next
lower open outlet on the same side by the
lubricant volume of the upper closed outlets.
Per stroke and outlet:
approx. 0.2 cm³ (SSV, SSV-E and SSVL)
approx. 0.07 cm³ (SSVM)
of lubricant is supplied.
NOTICE
Damage to the superior machine
- For metering devices with indicator pin
(monitoring K, KA, KN) the metering
volume reduces following the specifica-
tions in the Technical data.
- Outlets marked with the following sym-
bols must not be closed, as otherwise
the metering device will block.
Maximum number of outlets that can be
crossported internally per side of the meter-
ing device:
Metering device size 6 = 2
Metering device size 12 = 5
Metering device size 16 = 7
Metering device size 18 = 8
Metering device size 20 = 9
Metering device size 22 = 10
Further increasing of the output per outlet is
possible only by an external combining, e.g.
by means of a T-piece or by using metering
devices with bypass bores.
NOTICE
Risk of damage to the superior machine
and to the metering device
Closure screws on piston level must not be
removed to change the output volume.