1.15 Initial commissioning / daily start-up
Ensure that:
○
All safety devices are completely available
and functional.
○
All connections are correctly connected.
○
All parts are correctly installed.
○
All components used must be designed
according to the maximum operating
pressure and the maximum respectively
minimum ambient temperature.
○
No parts of the centralized lubrication
system may be subjected to torsion,
shear, or bending.
○
Check all parts prior to their usage for
contamination and clean, if necessary.
○
Lubricant lines should be primed with
lubricant prior to installation. This makes
the subsequent ventilation of the central-
ized lubrication system easier.
○
Observe the specified tightening torques.
When tightening, use a calibrated torque
wrench.
○
When working with heavy parts use suit-
able lifting tools.
○
Avoid mixing up or wrong assembly
of dismantled parts. Mark these parts
accordingly.
1.16 Cleaning
○
Risk of fire and explosion when using
inflammable cleaning agents Only use
non-flammable cleaning agents suitable
for the purpose.
○
Do not use aggressive cleaning agents.
○
Thoroughly remove residues of cleaning
agents from the product.
○
If possible, do not use steam jet and high
pressure cleaners.
○
Mark damp areas accordingly.
- 13 -
951-171-049
Version 02
EN
1. Safety instructions
1
Summary of Contents for SSV 10
Page 77: ...Notes...