6. Installation
6
- 55 -
951-171-049
Version 02
6.4.3 SSVD, SSVD-E and SSVDL
metering devices
The output of the SSV, SSVD-E and SSVDL
metering devices can be adapted by using
different metering screws. An additional
adaptation is possible by closing unneeded
outlets with closure screws in case of SSVD
and SSVD-E or by using connection bars in
case of SSVDL metering devices
To change the output with metering screws
proceed as follows:
• Remove protective caps from the meter-
ing device
• Screw the required metering screw into
the corresponding outlet
• Repeat the procedure for all other
outlets.
Tightening torques, see corresponding table
in these instructions.
Fig. 21 Metering screws
180
140
100
80
60
8
40
14
20
30
1.80
1.40
1.00
0.80
0.60
0.40
0.30
0.20
0.14
0.08
cm
3
J
I
H
G
F
E
D
C
B
A
cm
3