5. Delivery, returns, and storage
4
5
5.5
Storage conditions for parts illed
with lubricant
The conditions mentioned in the follow-
ing will have to be adhered to when storing
products filled with lubricant,
5.5.1 Storage period of up to 6 months
The filled products can be used without hav-
ing to take further measures
.
5.5.2 Storage period from 6 to 18
months
Lubrication pump
• Connect the lubrication pump electrically
• Switch the lubrication pump on and let it
run, e.g. by triggering an additional lubri-
cation, until about 4 cm³ of lubricant will
leak from each pump element
• Disconnect the lubrication pump from the
power supply
• Remove and dispose of leaked lubricant
Metering device
• Remove all lubrication lines and closure
screws, if any
• Connect the lubrication pump primed
with new lubrication grease suitable for
the application purpose to the metering
device
• Let the lubrication pump run until new
lubricant leaks from the outlets of the
metering device/lubrication lines
• Remove leaked lubricant
• IReinstall closure screws where applicable
Feed lines
• Dismantle preassembled lubrication lines
• Ensure that both lubrication line ends
remain open
• Prime lubrication lines with new lubricant
5.5.3 Storage period exceeding 18
months
To avoid dysfunctions consult the manufac-
turer before commissioning. The general
procedure to remove the old grease filling
corresponds to that of a storage period from
6 to 18 months.