background image

 

 

8

 

Codes number 12, 13, 14 and 15 are the next codes to be configured. These codes will be completed according to the conditions that have to be fulfilled to start 

and stop the unit workings. 

In order to use this table correctly; first read the options until you find the one you are interested in. Then, complete the codes 12, 13, 14 and 15, following the 

instructions for the chosen option. 
 

Table 2. Configuration codes 12, 13, 14 and 15    

 
What do you want to do? 

a)  Engine start just by programme:  

 

 

 

options 1, 2 and 3 

b)  Engine start just by external order:   

 

 

options 4, 5, 6 and 7 

c)  Engine start just external order and programme: 

options 7, 8, 9,10 and 11. 

 

NOTES: 

The Conditional Stop function interrupts both the working of the engine and the current programme, restarting when the signal stops. For example, if a sensor 

is placed in a well where water is being pumped, and this sensor gives us a signal when there is no water, when this signal is received by the programmer through 
input 2, the working will be interrupted until it stops. That is to say, until the sensor indicates that water is available in the well.  

 

 

 

 

 

 

 

 

 

 

 

 

Detection delay at input 2 

 

 Start/stop function at input 1, or conditional stop at input 2 

Detection delay at input 1 

 

 

 

 

Engine only working if input 1 & a programme are activated 

 

 

 

 

 

 

 

 

 

 

Options 

Input/s to be used 

Code 12 

Code 13 

Code 

14 

Code 

15 

On activating 

input 1… 

On 

deactivating 

input 1… 

On 

deactivating 

input 2… 

On deactivating 

input 2… 

1.

  The engine only starts 

and stops by programme. 

Use neither input 1 
nor input 2. 

                   
                     -                               

 

NO 

2.

 

The engine starts and 

stops by programme, but it 
can also stop by external 
order. 

Connect the 
external stop 
element to input 2.

 

 
 
                     - 

Enter the number of 
seconds that have 
to go by before a 
change is taken into 
account at input 2.

 

NO 

NO 

The engine 
stops. 

3.

  The engine starts and 

stops by programme, with 
conditional stop by external 
signal. 

Connect the 
external stop 
element to input 2.

 

   
 
                     - 

Enter the number of 
seconds that have 
to go by before a 
change is taken into 
account at input 2.

 

YES 

NO 

The engine 
working is 
interrupted 
(conditional 
stop)

 

The engine 
working is 
restarted if any 
programme or 
sector is 
activated.

 

4.

  The engine starts by 

external signal (it can only be 
stopped manually). 

Connect the 
external start 
element to input 1.

 

Enter the number of 
seconds that have to go 
by before a change is 

 
 
                    - 

NO 

NO 

The engine 
starts 

Summary of Contents for AGRONIC diesel

Page 1: ...nerators It has got 4 inputs to start stop by external order conditional stop oil pressure gauge or battery charge petrol and securities such as levels pressure gauges cylinder head temperature etc It has also got 6 relay outlets 3 for the start stop and engine ignition and other 3 that can adopt one of the following 7 combinations of outlets 1ª Fertiliser Electropump Breakdown indica tion 2ª Fert...

Page 2: ... access it The sections of consultation programming change of time manual activation of programmes and manual activation of sectors are accessed from the main menu The values displayed in these sections go with an identifying code To choose an option from this menu press the or keys until the screen shows the code of the desired option Press the C key to enter this option Press the and keys to mod...

Page 3: ...re 0º C to 45º C 0 5 Kg Parameters programmes It can not be erased Humidity 85 Height 2000 m Pollution Grade II DECLARATION OF CONFORMITY It follows the 89 336 CEE Guidelines for the Electromagnetic compatibility and the 73 23 CEE Guidelines of Low Tension for the Fulfilment of the Product Security The fulfilment of the specifications was demonstrated as indicated in the Official Diary of the Euro...

Page 4: ...s when the engine is not working and is not lit when it is working If the unit conditions indicate that the engine is working but input 3 is disconnected the engine stops and the programme is deactivated The programmer goes to the consultation code C1 showing the intermittent letters PA on the screen until the C key is pressed If on giving the order of starting to the engine it detects that there ...

Page 5: ...y open it is connected directly to output 2 If the electrovalve is normally closed it will be connected to outlet 3 With the electrovalve normally open this one is closed during the final time of the working If the electrovalve is normally closed this one is opened at the beginning of the working and closed at the end Outlet 3 Diesel engine ignition It is to be connected to the terminal cable 15 5...

Page 6: ... essential to put a valid code in this section If there is no valid value the programmer does not accept the petitions of engine starting and the screen blinks constantly Table 1 Outlet configuration Configuration number Outlet number Outlet function 1 4 5 6 Fertiliser Pump Breakdown indication 2 4 5 6 Fertiliser Warm up Breakdown indication 3 4 5 6 Fertiliser Pump Warm up 4 4 5 6 Warm up Pump uni...

Page 7: ...7 CONFIGURATION 5 CONFIGURATION 6 CONFIGURATION 7 ...

Page 8: ...hat water is available in the well Detection delay at input 2 Start stop function at input 1 or conditional stop at input 2 Detection delay at input 1 Engine only working if input 1 a programme are activated Options Input s to be used Code 12 Code 13 Code 14 Code 15 On activating input 1 On deactivating input 1 On deactivating input 2 On deactivating input 2 1 The engine only starts and stops by p...

Page 9: ...ter the number of seconds that have to go by before a change is taken into account at input 1 NO YES The engine starts if there is an activated programme 9 The engine starts by external signal only if a programme is working It stops when this signal ends or by end of programme Connect the external start element to input 1 Enter the number of seconds that have to go by before a change is taken into...

Page 10: ...ed From 0 to 250 seconds 11 Delay in the detection of engine breakdown indicate the delay in the detection of input 3 in order to detect a breakdown in the oil pressure diesel or in the battery charge petrol From 0 to 250 seconds 12 Delay in the activation of input 1 Start or Start Stop according to code 14 From 0 to 250 seconds 13 Delay in the activation of input 2 Stop or Conditional Stop accord...

Page 11: ...on about the evolution of the programme which is activated Table 5 Consultation option sections CODE FUNCTION C1 Unit time breakdown conditional stop C2 Time left before the first sector is activated C3 Time left before the second sector is deactivated C4 Activated inputs C5 Total time the engine has been working Press the C key to go from one code to the next one Press the C and keys at the same ...

Page 12: ...ngine is working it would mean that a programme has not finished yet or a sector has been activated manually Whatever the problem is the new programme is the one which is taken into account not paying any attention to the previous one The 00 00 starting time is not valid Code P4 The duration in hours and minutes of the activation of sector number 1 is to be entered here The maximum time is 23 59 C...

Page 13: ...gation is the time there must not be fertilisation before the end of the irrigation in order to clean the pipes Configuration code 1 The fertilisation will be started when the fertilisation time plus the post irrigation to finish the irrigation is left If the addition of both times is superior to the irrigation time fertiliser will be injected during the whole irrigation 7 8 STOP Press the C and k...

Page 14: ...14 8 FUNCTION CHART ...

Reviews: