8
Codes number 12, 13, 14 and 15 are the next codes to be configured. These codes will be completed according to the conditions that have to be fulfilled to start
and stop the unit workings.
In order to use this table correctly; first read the options until you find the one you are interested in. Then, complete the codes 12, 13, 14 and 15, following the
instructions for the chosen option.
Table 2. Configuration codes 12, 13, 14 and 15
What do you want to do?
a) Engine start just by programme:
options 1, 2 and 3
b) Engine start just by external order:
options 4, 5, 6 and 7
c) Engine start just external order and programme:
options 7, 8, 9,10 and 11.
NOTES:
The Conditional Stop function interrupts both the working of the engine and the current programme, restarting when the signal stops. For example, if a sensor
is placed in a well where water is being pumped, and this sensor gives us a signal when there is no water, when this signal is received by the programmer through
input 2, the working will be interrupted until it stops. That is to say, until the sensor indicates that water is available in the well.
Detection delay at input 2
Start/stop function at input 1, or conditional stop at input 2
Detection delay at input 1
Engine only working if input 1 & a programme are activated
Options
Input/s to be used
Code 12
Code 13
Code
14
Code
15
On activating
input 1…
On
deactivating
input 1…
On
deactivating
input 2…
On deactivating
input 2…
1.
The engine only starts
and stops by programme.
Use neither input 1
nor input 2.
-
-
NO
-
-
-
-
2.
The engine starts and
stops by programme, but it
can also stop by external
order.
Connect the
external stop
element to input 2.
-
Enter the number of
seconds that have
to go by before a
change is taken into
account at input 2.
NO
NO
-
-
The engine
stops.
-
3.
The engine starts and
stops by programme, with
conditional stop by external
signal.
Connect the
external stop
element to input 2.
-
Enter the number of
seconds that have
to go by before a
change is taken into
account at input 2.
YES
NO
-
-
The engine
working is
interrupted
(conditional
stop)
The engine
working is
restarted if any
programme or
sector is
activated.
4.
The engine starts by
external signal (it can only be
stopped manually).
Connect the
external start
element to input 1.
Enter the number of
seconds that have to go
by before a change is
-
NO
NO
The engine
starts
-
-
-