background image

 

 

12

programmer has started the engine. This spot does 
not appear if the engine has been started without 
using the programmer. 

This count can start again at 0 using the 

“configuration - code 3”. 

 
 

7.3. PROGRAMMING (Px) 

 

The desired values for every one of the five 

possible programmes are entered at Programming. 
The programming is divided into five options in the 
main menu: P1, P2, P3, P4 and P5. Choose the option 
according to the programme to be acceded. There are 
the same sections within each section.  

 

Table 6. Programming option sections 

CODE  FUNCTION 

P1 

How often it activates. 

P2 

Days left until the following activation. 

P3 

Starting time. 

P4 

Activation time of the first sector. 

P5 

Activation time of the second sector. 

 
Press the “C” key to go from one section to 

another. Press the “+” and “-” keys to modify values. 
Press the “C” and “+” key at the same time to go 
back to the Main Menu.  

 

-  Code P1: The activation frequency is to be entered 

in days, that is to say, the number of days this 
programme has to be activated. If number 1 is 
entered, the programme will be activated every 
day, if number 2 is entered, it will be activated one 
day yes, one day no, etc. The maximum is 15 days. 
If a 0 is entered the programme will  never be 

activated automatically. 

 

       Example 3.- Programming screen 

P 1         0 3 

 

 
-  Code P2: To change the days that are left before 

the programme is activated. For example, if it is to 
be activated every 7 days, but we want it to activate 
tomorrow, a  1 is to be entered, which means that 
there one day left for it to activate. With a 0, the 
programme is activated on the current day. This is 

the only section which is updated by the unit every 
day. 

 
-  Code P3: The time of the day when the programme 

is to start working is indicated here, in hours and 
minutes. When the programmer clock reaches this 
time, the programme will be activated, starting the 
engine if it is not working in this moment. If the 
engine is working, it would mean that a programme 

has not finished yet or a sector has been activated 
manually. Whatever the problem is, the new 
programme is the one which is taken into account, 
not paying any attention to the previous one. The 
00:00 starting time is not valid. 

 

-  Code P4: The duration, in hours and minutes, of 

the activation of sector number 1 is to be entered 
here. The maximum time is 23:59. 

 

-  Code P5: The time, in hours and minutes, sector 

number 2 has to be activated is to be entered here. 
The maximum time is 23:59.

 

 

 

7.4. CHANGE CLOCK TIME (HO) 

 

In this option there is just one section, HO, which 

displays the programmer clock time. This time can be 
changed with the “+” and “-“ keys. Press the “C” and 
“+” keys at the same time to go back to the Main 
Menu. 

 
 

7.5. MANUAL PROGRAMMES (AP) 

 

In this option there is just one section, AP. Use 

the “+” and “-“ keys to select the programme number. 
Then, press the “C” key to stop the selected 
programme if it is working or to start it if it is stopped. 
The number of the selected programme goes to 0 
waiting for the selection of a new programme.  

When a programme is selected, a spot on its left 

indicates that the programme is already activated. 

If the programme which is to be started lacks any 

of the basic parameters to be activated (Time 1 in the 
case of a fertilisation, for example), the programme 
order of start will not be taken into account and the 
programmer does not display a 0 in the number of the 
selected programme. 

If a programme is activated manually when 

another one is already working, the one which is 
working is deactivated and the one which was 
activated manually starts to work.  

The fact of activating a programme manually 

does not affect the days that are left for the 
programme to be activated.  

A spot appears at the left of the displayed time at 

the consultation codes C2 and C3, to indicate that the 
programme has been activated manually.  

Press the “C” and “+” keys at the same time to 

go back to the Main Menu. 

Manual programmes are not affected by the 

“configuration  - code 15” value and are activated 
independently of the state of input 1. 

 

Summary of Contents for AGRONIC diesel

Page 1: ...nerators It has got 4 inputs to start stop by external order conditional stop oil pressure gauge or battery charge petrol and securities such as levels pressure gauges cylinder head temperature etc It has also got 6 relay outlets 3 for the start stop and engine ignition and other 3 that can adopt one of the following 7 combinations of outlets 1ª Fertiliser Electropump Breakdown indica tion 2ª Fert...

Page 2: ... access it The sections of consultation programming change of time manual activation of programmes and manual activation of sectors are accessed from the main menu The values displayed in these sections go with an identifying code To choose an option from this menu press the or keys until the screen shows the code of the desired option Press the C key to enter this option Press the and keys to mod...

Page 3: ...re 0º C to 45º C 0 5 Kg Parameters programmes It can not be erased Humidity 85 Height 2000 m Pollution Grade II DECLARATION OF CONFORMITY It follows the 89 336 CEE Guidelines for the Electromagnetic compatibility and the 73 23 CEE Guidelines of Low Tension for the Fulfilment of the Product Security The fulfilment of the specifications was demonstrated as indicated in the Official Diary of the Euro...

Page 4: ...s when the engine is not working and is not lit when it is working If the unit conditions indicate that the engine is working but input 3 is disconnected the engine stops and the programme is deactivated The programmer goes to the consultation code C1 showing the intermittent letters PA on the screen until the C key is pressed If on giving the order of starting to the engine it detects that there ...

Page 5: ...y open it is connected directly to output 2 If the electrovalve is normally closed it will be connected to outlet 3 With the electrovalve normally open this one is closed during the final time of the working If the electrovalve is normally closed this one is opened at the beginning of the working and closed at the end Outlet 3 Diesel engine ignition It is to be connected to the terminal cable 15 5...

Page 6: ... essential to put a valid code in this section If there is no valid value the programmer does not accept the petitions of engine starting and the screen blinks constantly Table 1 Outlet configuration Configuration number Outlet number Outlet function 1 4 5 6 Fertiliser Pump Breakdown indication 2 4 5 6 Fertiliser Warm up Breakdown indication 3 4 5 6 Fertiliser Pump Warm up 4 4 5 6 Warm up Pump uni...

Page 7: ...7 CONFIGURATION 5 CONFIGURATION 6 CONFIGURATION 7 ...

Page 8: ...hat water is available in the well Detection delay at input 2 Start stop function at input 1 or conditional stop at input 2 Detection delay at input 1 Engine only working if input 1 a programme are activated Options Input s to be used Code 12 Code 13 Code 14 Code 15 On activating input 1 On deactivating input 1 On deactivating input 2 On deactivating input 2 1 The engine only starts and stops by p...

Page 9: ...ter the number of seconds that have to go by before a change is taken into account at input 1 NO YES The engine starts if there is an activated programme 9 The engine starts by external signal only if a programme is working It stops when this signal ends or by end of programme Connect the external start element to input 1 Enter the number of seconds that have to go by before a change is taken into...

Page 10: ...ed From 0 to 250 seconds 11 Delay in the detection of engine breakdown indicate the delay in the detection of input 3 in order to detect a breakdown in the oil pressure diesel or in the battery charge petrol From 0 to 250 seconds 12 Delay in the activation of input 1 Start or Start Stop according to code 14 From 0 to 250 seconds 13 Delay in the activation of input 2 Stop or Conditional Stop accord...

Page 11: ...on about the evolution of the programme which is activated Table 5 Consultation option sections CODE FUNCTION C1 Unit time breakdown conditional stop C2 Time left before the first sector is activated C3 Time left before the second sector is deactivated C4 Activated inputs C5 Total time the engine has been working Press the C key to go from one code to the next one Press the C and keys at the same ...

Page 12: ...ngine is working it would mean that a programme has not finished yet or a sector has been activated manually Whatever the problem is the new programme is the one which is taken into account not paying any attention to the previous one The 00 00 starting time is not valid Code P4 The duration in hours and minutes of the activation of sector number 1 is to be entered here The maximum time is 23 59 C...

Page 13: ...gation is the time there must not be fertilisation before the end of the irrigation in order to clean the pipes Configuration code 1 The fertilisation will be started when the fertilisation time plus the post irrigation to finish the irrigation is left If the addition of both times is superior to the irrigation time fertiliser will be injected during the whole irrigation 7 8 STOP Press the C and k...

Page 14: ...14 8 FUNCTION CHART ...

Reviews: