background image

 

13

7.6. MANUAL SECTORS (AS) 

 

 

This option has just got one section, AS. The 

screen displays a number which corresponds to the 
sector number which has to be used. Use the “+” and 
“-“ keys to modify it. Press the “C” key to activate the 
sector if it is stopped and vice versa. 

If the programmer is at conditional stop, sectors 

can be neither activated nor deactivated manually. 
Also, if a sector activation which is not valid is done (at 
fertilisation, activation of sector number  2 without 
number 1 being activated, for example), it is not taken 
into account. 

A spot at the left of the sector number indicates 

that this sector is already working.  

A spot appears at the left of the displayed time at 

the consultation codes C2 and C3, to indicate that the 
programme has been activated manually. The 
displayed time will be 00:00, making it different from a 
manual programme. Press the “C” and “+” keys at 
the same time to go back to the main menu. 

If the engine is started by the activation of input 

1, the first sector will appear as activated (as this is 
so), but it can not be deactivated manually while input 
1 is activated.  

 
 

7.7. FERTILISATION TIME 

 

 

This section is only to be taken into account if the 

unit uses irrigation with fertiliser. 

Post-irrigation is the time there must not be 

fertilisation before the end of the irrigation, in order to 
clean the pipes (Configuration - code 1-).  

The fertilisation will be started when the 

fertilisation time plus the post-irrigation to finish the 
irrigation is left. If the addition of both times is superior 
to the irrigation time, fertiliser will be injected during 
the whole irrigation. 

 

 
 
 

7.8. STOP 

 

 

Press the “C” and “-” keys at the same time for a 

sudden stop of the engine, stopping any activity which 
is taking place. A blinking STOP message will be 

displayed on the screen. The unit is to be activated 
manually.  

In this way, the programmer only allows 

consultations and change of parameters and 
programmes, but any engine start order is not taken 
into account. The screen also keeps blinking to 
indicate the STOP state.  

Press the “C” and “-” keys at the same time to go 

back to the automatic working of the unit. The screen 
stops blinking and the start orders are taken into 
account again.  

7.9. PROGRAMME PATTERN 

 

PROGRAMME 1 

How often it activates 

 

Starting time 

 

Time 1 

 

Time 2 

 

First activation date 

 

 

PROGRAMME 2 

How often it activates 

 

Starting time 

 

Time 1 

 

Time 2 

 

First activation date 

 

 

PROGRAMME 3 

How often it activates 

 

Starting time 

 

Time 1 

 

Time 2 

 

First activation date 

 

 

PROGRAMME 4 

How often it activates 

 

Starting time 

 

Time 1 

 

Time 2 

 

First activation date 

 

 

PROGRAMME 5 

How often it activates 

 

Starting time 

 

Time 1 

 

Time 2 

 

First activation date 

 

Summary of Contents for AGRONIC diesel

Page 1: ...nerators It has got 4 inputs to start stop by external order conditional stop oil pressure gauge or battery charge petrol and securities such as levels pressure gauges cylinder head temperature etc It has also got 6 relay outlets 3 for the start stop and engine ignition and other 3 that can adopt one of the following 7 combinations of outlets 1ª Fertiliser Electropump Breakdown indica tion 2ª Fert...

Page 2: ... access it The sections of consultation programming change of time manual activation of programmes and manual activation of sectors are accessed from the main menu The values displayed in these sections go with an identifying code To choose an option from this menu press the or keys until the screen shows the code of the desired option Press the C key to enter this option Press the and keys to mod...

Page 3: ...re 0º C to 45º C 0 5 Kg Parameters programmes It can not be erased Humidity 85 Height 2000 m Pollution Grade II DECLARATION OF CONFORMITY It follows the 89 336 CEE Guidelines for the Electromagnetic compatibility and the 73 23 CEE Guidelines of Low Tension for the Fulfilment of the Product Security The fulfilment of the specifications was demonstrated as indicated in the Official Diary of the Euro...

Page 4: ...s when the engine is not working and is not lit when it is working If the unit conditions indicate that the engine is working but input 3 is disconnected the engine stops and the programme is deactivated The programmer goes to the consultation code C1 showing the intermittent letters PA on the screen until the C key is pressed If on giving the order of starting to the engine it detects that there ...

Page 5: ...y open it is connected directly to output 2 If the electrovalve is normally closed it will be connected to outlet 3 With the electrovalve normally open this one is closed during the final time of the working If the electrovalve is normally closed this one is opened at the beginning of the working and closed at the end Outlet 3 Diesel engine ignition It is to be connected to the terminal cable 15 5...

Page 6: ... essential to put a valid code in this section If there is no valid value the programmer does not accept the petitions of engine starting and the screen blinks constantly Table 1 Outlet configuration Configuration number Outlet number Outlet function 1 4 5 6 Fertiliser Pump Breakdown indication 2 4 5 6 Fertiliser Warm up Breakdown indication 3 4 5 6 Fertiliser Pump Warm up 4 4 5 6 Warm up Pump uni...

Page 7: ...7 CONFIGURATION 5 CONFIGURATION 6 CONFIGURATION 7 ...

Page 8: ...hat water is available in the well Detection delay at input 2 Start stop function at input 1 or conditional stop at input 2 Detection delay at input 1 Engine only working if input 1 a programme are activated Options Input s to be used Code 12 Code 13 Code 14 Code 15 On activating input 1 On deactivating input 1 On deactivating input 2 On deactivating input 2 1 The engine only starts and stops by p...

Page 9: ...ter the number of seconds that have to go by before a change is taken into account at input 1 NO YES The engine starts if there is an activated programme 9 The engine starts by external signal only if a programme is working It stops when this signal ends or by end of programme Connect the external start element to input 1 Enter the number of seconds that have to go by before a change is taken into...

Page 10: ...ed From 0 to 250 seconds 11 Delay in the detection of engine breakdown indicate the delay in the detection of input 3 in order to detect a breakdown in the oil pressure diesel or in the battery charge petrol From 0 to 250 seconds 12 Delay in the activation of input 1 Start or Start Stop according to code 14 From 0 to 250 seconds 13 Delay in the activation of input 2 Stop or Conditional Stop accord...

Page 11: ...on about the evolution of the programme which is activated Table 5 Consultation option sections CODE FUNCTION C1 Unit time breakdown conditional stop C2 Time left before the first sector is activated C3 Time left before the second sector is deactivated C4 Activated inputs C5 Total time the engine has been working Press the C key to go from one code to the next one Press the C and keys at the same ...

Page 12: ...ngine is working it would mean that a programme has not finished yet or a sector has been activated manually Whatever the problem is the new programme is the one which is taken into account not paying any attention to the previous one The 00 00 starting time is not valid Code P4 The duration in hours and minutes of the activation of sector number 1 is to be entered here The maximum time is 23 59 C...

Page 13: ...gation is the time there must not be fertilisation before the end of the irrigation in order to clean the pipes Configuration code 1 The fertilisation will be started when the fertilisation time plus the post irrigation to finish the irrigation is left If the addition of both times is superior to the irrigation time fertiliser will be injected during the whole irrigation 7 8 STOP Press the C and k...

Page 14: ...14 8 FUNCTION CHART ...

Reviews: