Solution A2: To reload the band
1. Take off the remaining band. Do not press RESET beforehand.
2. Press RESET
⑧
to set the machine back to origin position.
3. Reload the band. The indicator BAND
②
should go off then.
4. Press and hold RESET
⑧
to allow the machine to detect and set the starting position.
5. Press START
⑨
to restart the operation.
Solution A3: To offset the joint jam
1. Cut off the joint area.
2. Press RESET
⑧
to disarm the indicator BAND
②
.
3. Press START
⑨
to complete the work with the remaining band before the joint.
4. The machine will stop and BAND
②
goes ON because running out of band. Follow solution A2 to continue the
operation.
Solution A4: To offset the Feeding Malfunction.
1. Remove the jammed band.
2. Reload the band.
3. Press RESET
⑧
to set the machine to origin position. The indicator BAND
②
goes OFF.
4. Press and hold RESET
⑧
to allow the machine to detect and set the starting position.
5. Press START
⑨
to restart the operation.
Solution A5: To disarm feeding problem other than devices.
1. Fix the falling and other issue. Reload the band to the proper position.
2. Follow solution A4 to resume the operation.
Solution A6: To reset the counter
1. Press COUNT RESET
⑬
. Indicator COUNTER
④
goes OFF.
2. Press START
⑨
to restart the operation.
Solution A7: To make the machine in ready.
1. On the sewing machine panel, when changing the setting, if the SEWING
⑭
is not ON, press READY
⑮
to set
the sewing machine in ready condition.
2. Activate the Under Thread Counter on the sewing machine panel. When it sets to 0, the machine will pause (refer
to page 44 in the sewing machine operation manual). Exchange the under thread and press R (RESET)
⑩
.
3. Press RESET
⑧
. The indicator STOP
①
will go OFF.
4. Press START
⑨
to restart.
Solution A8: To fix the Limit Switch malfunctions.
1. Disconnect the air supply.
2. Turn off the main power.
3. Check the Limit Switch.
There are 2 limit switches on the feeding moving cylinder and puller hook individually.
Turn off the valve, and turn on the power. Push or pull the cylinder and hook to check if the indicator of the limit
switch goes ON. Adjust the position of those two devices and check the limit switch again. If the devices are in
position, but the indicator does not go ON, then replace a new limit switch.
P15
Summary of Contents for ASP-EBJ100
Page 1: ...ASP EBJ100 INSTRUCTIONS BOOK PARTS LIST ORIGINAL...
Page 2: ......
Page 3: ...ENGLISH ENGLISH...
Page 33: ...P5...
Page 34: ...P6...
Page 35: ...P7...
Page 36: ...P8...
Page 37: ...P9...
Page 38: ...P10...
Page 39: ...P11...
Page 40: ...P12...
Page 41: ...P13...
Page 42: ...P14...
Page 43: ...P15...
Page 44: ...P16...
Page 45: ...P17...
Page 46: ...P18...
Page 47: ...P19...
Page 48: ...P20...
Page 49: ...P21...
Page 50: ...P22...
Page 51: ...P23...
Page 52: ...P24...
Page 53: ...P25...
Page 54: ...P26...
Page 55: ...P27...