
Simrad PI32
56
857-164636 / Rev.A
How to define sensor offsets
Only the Depth and Spread sensors can have their offset values
adjusted. The purpose is to allow you to compensate for known
deviations.
You may wish to insert a Depth sensor offset to line up the
depth readings from the sensor with those from your echo
sounder. If the echo sounder transducer is located X meters
below the surface, the Depth sensor should have the same offset
value.
Note:
If you have performed a Depth sensor calibration, you will see
than an offset value may already be present. This value has been
provided by the calibration routine.
1
On the PI32, press the
MENU
button to open the main
menu.
2
Open the
Setup
menu, and select
Sensor
alarm/calibration
.
3
At the bottom of the dialogue, enter the required values.
4
Press the
ENT
button to save the parameters and exit.
Related topics
→
Offset adjust, setup, page 170