Display modes
39
857-164636 / Rev.A
The second lines shows:
•
The current AGC status (Automatic Gain Control)
•
The status off the hydrophone cable. A yellow circle means
that the cable is serviceable. A black circle means that it has
broken, while a red circle indicates a short circuit.
•
CH/R: The channel number of the sensor from which data
was last received.
•
E: Error code for systems manlfunctions. The error code “0”
signifies that no system error is present.
(E)
Frequency spectrum for frequencies on the 00 to 15 band.
Select the desired band by pressing the respective
-
or
+
buttons.
Wait for the unit to update the display. The graph represents the
associated background noise and the signal strength of the band
selected.
(F)
Gain indicator
(G)
Gain indicators for the three current sensors. The green field
indicates that the detection level is within normal specifications.
The red field indicates that the signal level is currently over the
detection threshold (DT).
(H)
Information lines 3 and 4. The top line provides the
following information:
•
Geographical position (longutide)
•
Current course
•
Current depth
•
Current time.
The bottom line shows:
•
Geographical position (latitude)
•
Current speed
•
Current surface temperature
To change status display parameters
The parameters are fixed, and they can not be changed.
Related topics
→
Receiver setup, page 174