References
163
857-164636 / Rev.A
Input
By default, the PI32 is only equipped with one NMEA interface
connector. For this reason, you can only receive data from one
peripheral device. However, this device may provide you with
more than one type of information. For example, GPS systems
will provide you with position, course, speed and navigational
information, and these telegrams are transmitted sequentially on
the same serial line using different telegram types.
If you do not use you
Remote
connector to interface a
secondary display, you can define this output as an NMEA
interface. For more information, refer to the
Interface setup
Remote/Alarm
setup page.
Position:
Select which telegram you wish to use to receive
position data; either GLL, RMA, RMC or GGA. Then, switch
the interface on or off.
Course:
Select which telegram you wish to use to receive
course data; either RMA, RMC or VTG. Then, switch the
interface on or off.
Speed:
Select which telegram you wish to use to receive speed
data; either RMA, RMC or VTG. Then, switch the interface on
or off.
Navigation:
The telegrams used to receive navigational data are
fixed, and the PI32 will receive APB, RMB and XTE telegrams.
Switch the interface on or off.
Water temperature:
The telegram used to receive water
temperature data is fixed, and the PI32 will receive this
information using the MTW telegram. Switch the interface on
or off.