References
167
857-164636 / Rev.A
Interface setup remote/alarm
The PI32is equipped with only one NMEA interface port, but
the
Remote
interface can also be used for NMEA interface
provided that the remote display is not used. This setup page is
used to define the inputs and outputs if the
Remote
interface is
used as an NMEA port.
Position:
Select which telegram you wish to use to receive
position data; either GLL, RMA, RMC or GGA. Then, switch
the interface on or off.
Course:
Select which telegram you wish to use to receive
course data; either RMA, RMC or VTG. Then, switch the
interface on or off.
Speed:
Select which telegram you wish to use to receive speed
data; either RMA, RMC or VTG. Then, switch the interface on
or off.
Navigation:
The telegrams used to receive navigational data are
fixed, and the PI32 will receive APB, RMB and XTE telegrams.
Switch the interface on or off.
Water temperature:
The telegram used to receive water
temperature data is fixed, and the PI32 will receive this
information using the MTW telegram. Switch the interface on
or off.
Output
The output pins on the
Remote
connector can be used as an
alarm output.
Output pin:
The PI32 will allow provide an alarm output when
this setting is enabled.
Alarm stand-by level:
???