User manual for digital clock SWZ-W610
works properly on baud rates higher than 19200. This parameter can be set to one
of values:
”Std”
- answer as quick as possible, no additional delay
” 10c”
” 20c”
” 50c”
”100c”
”200c”
- answer delayed of 10, 20, 50, 100 of 200 chars respectively, where
one character time depends on selected baud rate
In the most cases parameter
”rESP”
should be set to
”Std”
(no additional delay).
Unfortunately for some third party RS-converters
”rESP”
should be adjusted
experimentally. Table 7.1 contains most frequently used values.
”bAud” parameter
“38.4”
“57.6”
“115.2”
”rESP” parameter
“ 10c”
“ 20c”
“ 50c”
Tab.7.1.
Settings of
”rESP”
parameter
7.3.7.
”Scod” parame
ter
This parameter defines user password (4-digits number). If this parameter is set at value
“0000”
, user password is turned off.
If the user do not remember his password, the access to the menu is possible
by the “one-use password”. To get this password please contact with
Marketing Division. “Single use password” can be used only one time, after
that it is destroyed. Entering this password causes in clearing of user
password, it means sets the user password to „0000”.
The “one-use password” can be used
ONE TIME ONLY
, it is impossible to use it
again! The “one-use password” can be restored by Service Division only.
7.3.8.
”Edit”
parameter
This parameter allows to change the edition mode of numerical parameters:
”dig”
- the change to “by digit” mode,
”Slid”
- slide change mode.
7.3.9.
”dEFS”
parameter
This setting allows to restore the factory settings of the device. To get the access to this
option special password is required: „5465”, next the device displays acknowledge question
„SEt?”
. Press
[ENTER]
to acknowledge the restoring of factory settings or
[ESC]
to cancel.
7.3.10.
”SErv” menu
This menu contains the parameters for authorized service only. To enter this menu
proper service password must be entered. Improper settings can causes of damage of the
device.