background image

User manual for digital clock SWZ-W610

7.3.4. 

  

    “Func” menu

  

This menu allows to set operation mode:

“dAtE”

- this parameter allows to switch on/off displaying of the date

“yEAr”

- this  parameter allows to switch on/off  displaying of the year while date is 

showed

”oFF”

- displaying of the year is off

”on”

- displaying of the year is on

“thEr”

-   this   parameter   allows   to   switch   on/off   displaying   of   the   temperature.   If 
temperature sensor is not connected to the {

THERM

} input, or if it is damaged, 

the signs „

- - - -

”  will be displayed in place of current temperature.

7.3.5. 

  

    “dCF” menu

  

This menu contains parameters corresponding to cooperation with DCF77 module.

”modE”

- this parameter enables synchronization of internal clock with DCF77 signal, and 

allows to define resting state of the module output. There are available values:

”oFF”

- synchronization is off

”L Lo”

-  synchronization is on, the resting state of DCF module output is LOW 

”L Hi”

-  synchronization is on, the resting state of DCF module output is HIGH

If it is impossible to synchronize clock with DCF signal within 7 days (no signal, or 

errors in received data) the double dot between hour and minutes will start to pulse 

in asymmetrical mode (lighting time much shorter than time of dimming).

”diSP”

- this parameter allows to on/off the signalisation of DCF77 module output state by 

LED ( digital point of the most right digit). Lighting LED means high state of DCF 

output. This parameter can be set to:

”oFF”

- signalisation is off,

”on”

- signalisation is on.

”Sync”

- this submenu allows to check the time of the last synchronization,  the number of 

correct received frames and bits of  DCF77 signal. 

hours:minutes

 

seconds

- the time of last synchronization

day.month.

year 

- the date of last synchronization,

”F NF”

- number of received frames, where NF is the number of 

frames in range 0 to 3

”b NB”

-  number of received bits, where NB is the number of bits 

in range 0 to 59

The   manner   of   presentation   of   these   informations   is   showed   in

  Figure 7.1.   The   first 

information   after   selection  

”Sync”  

(and   pressing   the  

„ENTER”  

button)   is   the   time   of   last 

synchronization (e.g. 23:25:00). Subsequent pressings the [

v

] button, cause in displaying of 

another informations in showed order; the date of last synchronization (e.g. 19

th

 of may 2005), 

the number of correctly received frames  (e.g. 2 frames) and the number of collected bits of 

frame being received (e.g. 47 bits).

17

i

Summary of Contents for SWZ-W610

Page 1: ...for digital clock type SWZ W610 firmware version 1 01 or higher Read the user s manual carefully before starting to use the unit Producer reserves the right to implement changes without prior notice...

Page 2: ...ation of DCF77 module 12 7 DEVICE PROGRAMMING 14 7 1 PROGRAMMING MENU 14 7 2 PARAMETERS EDITION 14 7 2 1 Numeric parameters digit change mode 14 7 2 2 Numeric parameters slide change mode 15 7 2 3 Swi...

Page 3: ...up according to the application Incorrect configuration can cause defective operation which can lead to unit damage or an accident If in the case of a defect of unit operation there is a risk of a ser...

Page 4: ...mode only and internal battery preserves proper time counting even if device is turned off from power supply The SWZ W610 is designed to operate in closed rooms where relative humidity is lower than 9...

Page 5: ...on volatile memory EEPROM type Protection level IP 30 Housing type Housing material Housing dimensions Wall mounted aluminium methyl polimethacrylate 578 x 208 x 102 mm Operating temperature Storage t...

Page 6: ...y Protecting the power supply clamps against unauthorized persons must be taken into consideration 4 1 UNPACKING After removing the unit from the protective packaging check for transportation damage A...

Page 7: ...mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the case of a short circuit of the cable from the side of the unit the cable shall be protec...

Page 8: ...g induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equipped with anti interference protection systems e g RC type Use of screened...

Page 9: ...Earth terminal is 2 Nm Power supply connection must be made using 3 wire cord After installation power cord gland should be tighten up to prevent cable move Metal housing must be connected with PE gro...

Page 10: ...ry cloth In the case of more significant contamination use warm water with small amount of detergent to wet the cloth Using any other agents can cause permanent damage to the housing Product marked wi...

Page 11: ...tal temperature sensor module is connected to THERM input the device can display current temperature near the sensor The display can show only one of these parameters or can change them in sequence wi...

Page 12: ...f high air flow sunny places and near of artificial light sources like bulbs etc Due to possibility of electromagnetic noise while using long connection wires a temperature sensor should be equipped w...

Page 13: ...LED is on should be shorter than time while LED is dark The additional test of correct orientation of the aerial is number of received bits see parameter Sync of dCF submenu Aerial should be oriented...

Page 14: ...ion of ENTER button depend on present menu position if the name of some sub menu is displayed enter this sub menu name of the first parameter or next level sub menu is displayed if the name of some pa...

Page 15: ...ncel the changes press ESC button shortly after SEt is displayed After that device returns to the menu 7 2 3 Switch parameters LIST type Switch parameters can be described as a sets of values a lists...

Page 16: ...parameter to 00 causes in permanent displaying of time after switch device to display it dL d this parameter defines the displaying period of current date in format day month year in range from 1 to...

Page 17: ...eived data the double dot between hour and minutes will start to pulse in asymmetrical mode lighting time much shorter than time of dimming diSP this parameter allows to on off the signalisation of DC...

Page 18: ...to 199 If the value 0 is set then device responds to frames with address 255 FFh Every SWZ W610 connected to the same serial network should have its own address different from other devices addressed...

Page 19: ...ble by the one use password To get this password please contact with Marketing Division Single use password can be used only one time after that it is destroyed Entering this password causes in cleari...

Page 20: ...n 4 digit user password entering if it is different from 0000 thEr MENU ESC rS MENU ESC dEFS ENTER MENU ESC MENU ESC SErv Parameter edition ENTER MENU ESC ENTER ENTER MENU ESC Addr bAud mbAC rESP MENU...

Page 21: ...Monday etc 11h Yes 2000 2099 Year registry 12h Yes 1 12 Months registry 13h Yes 1 31 Days registry 14h Yes 0 23 Hours registry 15h Yes 0 59 Minutes registry 16h Yes 0 59 Seconds registry 17h Yes see d...

Page 22: ...eter in Func menu date displaying 0 disabled 1 enabled 39h Yes 0 1 yEAr parameter in Func menu display year while date 0 disabled 1 enabled 3Ah Yes 0 1 thEr parameter in Func menu temperature displayi...

Page 23: ...ield description ADDR Device address on modbus network FUNC Function code REG H L Starting address address of first register to read write Hi and Lo byte COUNT H L No of registers to read write Hi and...

Page 24: ...H 07 D5 00 05 00 17 EA BA This write causes by setting the date to 23th of may 2005 Device s answer ADDR FUNC REG H L COUNT H L CRC L H 01 10 00 01 00 03 D1 C8 4 Try to write improper value to registe...

Page 25: ...ng on 17 yEAr Enable disable of year displaying while date displaying on 17 thEr Enable disable of temperature displaying oFF 17 DCF77 signal receiver configuration dCF menu modE Enable disable of syn...

Page 26: ...User manual for digital clock SWZ W610 26...

Page 27: ...User manual for digital clock SWZ W610 27...

Page 28: ...SIMEX SIMEX Sp z o o ul Wielopole 7 PL 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex com pl e mail info simex com pl...

Reviews: