User manual - METER SRP-N1186
5.
FRONT PANEL DESCRIPTION
Symbols and functions of push-buttons:
Symbol used in the manual:
[ESC/MENU]
Functions:
•
Enter to main menu ( press and hold by at least 2 sec.)
•
Exit the current level and Enter to previous menu (or measure mode)
•
Cancel the changes made in parameter being edited
Symbol used in the manual:
[ENTER]
Functions
:
•
Start to edit the parameter
•
Enter to the sub-menu,
•
Confirmation of changes made in parameter being edited
Symbol used in the manual:
[^] [v]
Functions
:
• Change of the present menu,
• Modification of the parameter value,
• Change of the display mode.
6.
PRINCIPLE OF OPERATION
After turning the power supply on, device ID and software version are showed on the
display, next the controller goes to the measurement mode.
6.1.
MEASUREMENT MODE
In the measure mode, the measurement results, converted over selected characteristic,
are displayed on the LED display. The measurement range equal to the nominal range is
called:
nominal measurement range,
and the measurement range equal to the extended
nominal range is called:
permissible measurement range
(Figure 6.1, 6.2).
20
MENU
ESC
ENTER
MENU
ESC
ENTER
AL
R1
R2
RESET
infrared
receiver
alarm LED indicator (
AL
)
Thresholds exceeding
LED indicators (
R
)
display
programming pushbuttons
Summary of Contents for SRP-N1186