User manual - METER SRP-N1186
Register Write
Range
Register description
46h
Yes
see descr.
“
SEt2
” parameter in “
rEL1
” menu, no decimal point included –
lower word
47h
Yes
see descr.
“
SEtP
” parameter in “
rEL2
” menu, no decimal point included –
higher word
48h
Yes
see descr.
“
SEtP
” parameter in “
rEL2
” menu, no decimal point included – lower
word
49h
Yes
see descr.
“
HySt
” parameter in “
rEL2
” menu, no decimal point included –
higher word
4Ah
Yes
see descr.
“
HySt
” parameter in “
rEL2
” menu, no decimal point included –
lower word
4Bh
Yes
0 ÷ 5
“
modE
” parameter in “
rEL2
” menu:
0
- “
noAC
” mode;
1
- “
on
” mode;
2
- “
oFF
” mode;
3
- “
in
” mode;
4
- “
out
” mode;
5
- “
modb
” mode
4Ch
Yes
0 ÷ 999
“t on”
parameter in
“rEL2”
menu, expressed in tenth of seconds or
tenth of minutes depend on
“unit”
parameter - register no. 4Eh)
4Dh
Yes
0 ÷ 999
“toFF”
parameter in
“rEL2”
menu, expressed in tenth of seconds
or tenth of minutes depend on
“unit”
parameter - register no. 4Eh)
4Eh
Yes
0 ÷ 1
“unit”
parameter in
“rEL2”
menu:
0
- seconds;
1
- minutes
4Fh
Yes
0 ÷ 2
“AL”
parameter in
“rEL2”
menu:
0
- no changes;
1
- on;
2
- off
50h
Yes
see descr.
“
SEt2
” parameter in “
rEL2
” menu, no decimal point included –
higher word
51h
Yes
see descr.
“
SEt2
” parameter in “
rEL2
” menu, no decimal point included –
lower word
68h
Yes
0 ÷ 1
“
modE
” parameter in “
HOLd
” menu (type of detected changes):
0
- peaks;
1
- drops
69h
Yes
see descr.
“
PEA
” parameter in “
HOLd
” menu (minimum detectable change, no
decimal point included) – higher word
6Ah
Yes
see descr.
“
PEA
” parameter in “
HOLd
” menu (minimum detectable change, no
decimal point included) – lower word
6Bh
Yes
0 ÷ 199
“
timE
” parameter in “
HOLd
” menu,
maximum peaks' (or drops')
display time expressed in seconds
6Ch
Yes
0 ÷ 1
“
HdiS
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
6Dh
Yes
0 ÷ 1
“
H r1
” parameter in “
HOLd
” menu
:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
6Eh
Yes
0 ÷ 1
“
H r2
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
71h
Yes
0 ÷ 1
“
HOUt
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
77h
5
Yes
see descr.
The value of „
X
” coordinate of point
no. 1
of the user defined
characteristic, expressed in 0.1% – higher word
55