Safety
2
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol.
When you see this
symbol on your pump or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury.
warns about hazards that
will
cause serious
personal injury, death or major property damage if
ignored.
warns about hazards that
can
cause serious
personal injury, death or major property damage if
ignored.
warns about hazards that
will
or
can
cause
minor personal injury or property damage if ignored.
The label
NOTICE
indicates special instructions which
are important but not related to hazards.
1. To avoid risk of serious bodily injury due to electrical
shock or burns and property damage due to flooding,
read the safety instructions carefully before installing
the pump.
Burn Hazard. Battery acid is corrosive. Do
not spill on skin, clothing, or battery charger.
Wear eye
and head protection when working with battery. Connect
and disconnect DC output terminals only after removing
the charger from the AC outlet. Never allow the DC ter-
minals to touch each other.
Hazardous Voltage. Electrical shock can
cause severe injury or death.
Do not plug in or unplug
battery charger while standing on a wet floor or in water.
Be sure one hand is free when plugging in or unplugging
charger. If basement floor is wet, disconnect power to
basement before walking on floor.
Do not lift the pump by the electrical cord; lift pump
only by the discharge pipe, lifting ring or handle on the
pump. Lifting by the cord can damage the cord.
Risk of flooding. Make sure pump is
secured in sump to prevent movement and do not run
pump dry.
To do so will damage seals and can cause
leaking and property damage. Failure to secure the pump
in the sump may allow the pump to move, cause switch
interference and prevent the pump from stopping or start-
ing. Make sure the sump is clear of debris. Debris can
damage or plug the pump which can result in flooding.
2. Follow local and/or national plumbing and electrical
codes when installing the system. A ground fault cir-
cuit interrupter (GFCI) is recommended for use on
any electrical appliance submerged in water.
3. Use this system only for backup sump pump duty in a
residential application. It is not designed as a primary
sump pump.
Fire Hazard.
Keep sparks and flames away
from battery to prevent explosion or fire.
4. Pump clear water only with this pump.
5. Pump is permanently lubricated at the factory. Do not
try to lubricate it!
6. Keep the battery charger and battery box off of the
floor and in a dry, cool, well ventilated area.
NOTICE:
If a Carbon Monoxide (CO) sensor is
installed, it must be at least 15 feet away from battery
charger in order to avoid nuisance CO alarms. Please
refer to your CO detector’s installation guidelines for
more information.
SIMER warrants to the original consumer purchaser (“Purchaser”) of its products
that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below. Your origi-
nal receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product
covered by this warranty. This warranty shall not apply to acts of God, nor shall
it apply to products which, in the sole judgement of SIMER, have been subject
to negligence, abuse, accident, misapplication, tampering, alteration; nor due
to improper installation, operation, maintenance or storage; nor to other than
normal application, use or service, including but not limited to, operational fail-
ures caused by corrosion, rust or other foreign materials in the system, or oper-
ation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec-
tive product to the Retail outlet or to SIMER as soon as possible after the dis-
covery of any alleged defect. SIMER will subsequently take corrective action as
promptly as reasonably possible. No requests for service under this warranty
will be accepted if received more than 30 days after the term of the warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive rem-
edy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR
CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state
to state.
Simer Limited Warranty
SIMER • 293 Wright St. • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867 / 1-800-546-7867 • Fax: 1-800-390-5351