background image

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Shaded-pole motor is oil filled and sealed
for cooler running. Sleeve bearings on motor shaft never
need lubrication. Automatic reset thermal protection. Not
designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge:

Check Valve .......................1-1/4" slip / 1-1/2" slip
Hose ............................................................1-1/4"

NOTICE:

Do not reduce size of discharge pipe or

hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.

NOTICE:

This unit is not designed as a waterfall or

fountain pump, or for applications involving salt
water or brine! Use with waterfalls, fountains, salt
water or brine will void warranty.
Pump water only with this pump.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more infor-
mation, see your retailer or call customer service at 
1-800-468-7867.
1. Know the pump application, limitations, and

potential hazards.

2.

Do not use this pump in water with fish present. If
any oil leaks out of the motor it can kill fish.

3. Disconnect power before servicing.
4. Release all pressure within system before servic-

ing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and prop-

erly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volt (sin-
gle phase) and is equipped with an approved 
3-conductor cord and 3-prong, grounding-type
plug.

GPH (LPH) AT TOTAL FEET (M) OF LIFT

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

2944RP

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 571)

(7.3M)

No flow 

at height

shown

below

Individual

Motor

Branch

*Switch Setting

Full Load

Circuit

in inches (mm)

Series

HP

Amps

Req.(Amps)

On

Off

2944RP

1/2

5.5

15

8"(203)

3.5"(89)

Summary of Contents for 2944RP

Page 1: ...7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 1 800 546 7867 Fran ais Pages 8 12 Instalaci n Opera...

Page 2: ...larm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more infor mation see your retailer or call customer service at 1 800 468 7867 1 Know...

Page 3: ...for approved materials and for proper installation 2 Install pump in pit so that switch operating mechanism has maximum possible clearance 3 Pump should not be installed on clay earth or sand surfaces...

Page 4: ...discharge pipe etc could cause cycling 3 Pump will not remove all water If operating a pump manually and suddenly no water comes out of the discharge hose shut off the unit immediately The water leve...

Page 5: ...t Description Qty 2944RP 1 Power Cord Assembly 1 PS117 54 TSU 2 Motor 1 3 Volute Upper 1 PS1 31P 4 Screw 8 32x5 8 Phillips Pan Head 4 5 Impeller 1 RP0000911A 6 Volute Lower 1 PS1 30P 7 Screw 8 16x1 2...

Page 6: ...ty float switch Replace float switch Pump won t shut off Defective float switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle or ice in piping Float obstruct...

Page 7: ...return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Wa...

Page 8: ...eau de recherche des pannes de ce Manuel pour plus de renseignements concernant les probl mes courants des pompes de puisard et leurs rem des Pour de plus amples renseignements s adresser au d taillan...

Page 9: ...plastique Consulter les codes municipaux pour conna tre le mat riau approuv et pour proc der ad quatement l installation 2 Installer la pompe dans le puisard de fa on que le m canisme actionnant l int...

Page 10: ...suffisamment refroidi le disjoncteur se r armera automatiquement et le moteur red marrera Si le protecteur se d clenche constamment sortir la pompe du puisard et en d terminer la cause Une basse tensi...

Page 11: ...f D signation Qt 2944RP 1 Ensemble de cord n lectrique 1 PS117 54 TSU 2 Moteur 1 3 Volute sup rieure 1 PS1 31P 4 Vis t te cylindrique empreinte cruciforme n 8 32 x 5 8 de pouce 4 5 Impulseur 1 RP0000...

Page 12: ...ns Installer un clapet de retenue s arr te trop souvent la pompe Interrupteur du flotteur Remplacer l interrupteur du flotteur d fectueux La pompe refuse de Interrupteur du flotteur Remplacer l interr...

Page 13: ...de la pompe et l original du re u au d taillant Mettre la pompe au rebut conform ment la r glementation locale Exceptions la garantie limit e de douze 12 mois Produit P riode de garantie BW85P CM10 C...

Page 14: ...a de alto nivel de agua Consulte la Tabla de solu ci n de problemas contenida en este manual para infor maci n sobre problemas comunes de la bomba de sum idero y soluciones Para mayor informaci n visi...

Page 15: ...zo de manera que el mecanismo de operaci n del interruptor tenga el mayor juego posible 3 La bomba no debe ser instalada en arcilla tierra o superficies arenosas Saque las piedritas y arenillas que pu...

Page 16: ...obablemente el nivel del agua es muy bajo y la unidad ha dejado de cebar Riesgo de choque el ctrico Antes de intentar revisar porque la bomba ha dejado de funcionar desconecte la energ a el ctrica 2 S...

Page 17: ...nt 2944RP 1 Ensamblaje de cord n de corriente 1 PS117 54 TSU 2 Motor 1 3 Voluta superior 1 PS1 31P 4 Tornillo cabeza de cono achatado Phillips 8 32x5 8 4 5 Impulsor 1 RP0000911A 6 Voluta inferior 1 PS...

Page 18: ...la de retenci n marcha y se detiene con la tuber a demasiada frecuencia El interruptor del flotante Reemplace el interruptor del flotante est fallado La bomba no se Interruptor defectuoso Reemplace el...

Page 19: ...ndo manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas l...

Page 20: ......