28
1.1
INTRODUCTION
The new
“Rondò B”
series of cast iron
boilers, for heating and the production
of domestic hot water, has been
designed in compliance with the
European Directive CEE 92/42.
They use light oil and have a perfectly
balanced combustion with a very high
thermal efficiency for economical per-
formance.
1
BOILER DESCRIPTION
950
64
0
395
235
75
M1
M
U
C
E
R
S
=
=
100
550
960
30
735
460
Ø 1
30
730
1
300
1.2
DIMENSIONAL DETAILS
Fig. 1
1.3
TECHNICAL FEATURES
KEY
M1
Zone system flow
R 1” (UNI-ISO 7/1)
M
C.H. flow
R 1” (UNI-ISO 7/1)
R
C.H. return
R 1” (UNI-ISO 7/1)
S
Boiler filling-drain
Rp 1/2” (UNI-ISO 7/1)
E
D.C.W. inlet
Rp 3/4” (UNI-ISO 7/1)
C
Recirculation
Rp 3/4” (UNI-ISO 7/1)
U
D.H.W. outlet
Rp 3/4” (UNI-ISO 7/1)
Rondò B4
Rondò B5Rondò B4
Rondò B5
Nox: Class 3*
NOx: Class 3*
Output
kW
31,3
40,0
27,6
32,7
kcal/h
26.900
34.400
23.700
28.100
Input
kW
34,8
44,3
30,7
36,3
kcal/h
29.900
38.100
26.400
31.200
Sections
n°
4
5
4
5
Adsorbed power consumption
W
80
80
80
80
Maximum water head
bar
4
4
4
4
Water content
l
19,8
23,8
19,8
23,8
Smoke loss of head
mbar
0,16
0,21
0,07
0,13
Combustion chamber pressure
mbar
–0,02
–0,02
–0,02
–0,02
Suggested chimney depression
mbar
0,18
0,23
0,09
0,15
Smokes temperature
°C
188
185
145
145
Smokes flow
m
3
st/h
41,4
52,8
37,4
43,9
Smokes volume
dm
3
12
15
12
15
CO
2
%
12,5
12,5
12,8
12,9
Heating adjustment range
°C
30÷85
30÷85
30÷85
30÷85
D.H.W. adjustment range
°C
30÷60
30÷60
30÷60
30÷60
D.H.W. production
D.H.W. tank capacity
l
80
80
80
80
D.H.W. flow rate
∆
t 30°C **
l/h
880
930
790
930
Recovery time from 25°C to 55°C
min
10
10
10
10
D.H.W. tank max. water head
bar
6
6
6
6
Weight
kg
217
243
217
243
*Burner with low polluting emissions
** With the sanitary water at inlet temperature 15°C - Boiler temperature 80°C
Summary of Contents for Rondo B Series
Page 1: ...IT ES PT GB FR BE Rond B CERTIFICAZIONE DEL SISTEMA DI QUALITA AZIENDALE...
Page 54: ......
Page 55: ......