SensorIQEasy_UM_9752023110_NL_D_GB_V2_0
60
7.2.2
Graphics
tab
The
Graphics
tab graphically shows the operation in form of bar charts.
Each segment is displayed as a vertical bare, and the last will display the average (
avg
) of all
active segments.
- red: actual value of the measurement value
- yellow: maximum peak value during the last
logfile refresh time
.
Every time the logfile is written, this value will be reset to 0.
If the screen is clicked somewhere, the screen will “freeze”, and display
On hold.
Clicking again
will display the current value.
7.2.3
Action log
tab
In the
Action log
tab, the changed status of the bar is logged step-by-step. This is indicated with
the date and time the status change has occurred. Main messages:
-
HV TOO HIGH
: the measured value has exceeded the alarm set point
-
HV PRE WARNING
: the measured value has exceeded the warning set point
-
Errors Cleared
: the measured value has fallen below the alarm set point.
-
Warnings cleared
: the measured value has fallen below the warning set point.
7.2.4
Data log
tab
In the
Data log
tab, the average measurement value of the active segments of all available
measurement data of the bar is logged at fixed times (Uavg[kV]).
If the parameter
Datalogging
is activated, these values will also be saved in the manager log
file. The interval between logging is determined by the setting in the Manager IQ Easy. See user
manual of the Manager in Chapter 6.6.3
8 Maintenance
Warning:
- Disconnect the power supply before carrying out any work on the unit.
8.1 Cleaning the Sensor
- The Sensor is equipped with a compressed air connection. Using this supply a continuous air
flow can be blown across the sensor(s). This will prevent a dirt build up.
8.2 Cleaning a very filthy Sensor
- Clean the Sensor using a dry cleaning cloth. Do not use any liquids.
- See 5.5 if demounting the Sensor is required for cleaning/replacement.